Development of a simulation tool to assess heat pump integration in Canadian homes
Notice bibliographique
Résumé
Air-to-air heat pumps (ASHPs) can play an important role in reducing the greenhouse gas (GHG) emissions of Canadian homes, but their performance is highly dependent on sizing, integration, ASHP type, and building location and construction. Currently, the Heating Seasonal Performance Factor (HSPF2) is used to provide homeowners with an estimate of seasonal performance, but neglects many of the key factors above. More accurate estimations of ASHP performance for a given project are needed to provide homeowners with an improved understanding of performance potential for their unique context.Simulation tools can more accurately assess ASHP performance in a specific installation, taking into account variations in climate, building characteristics, and system configurations. However, many commonly used building simulation tools (e.g., TRNSYS, EnergyPlus) require significant effort and expertise to operate. This complexity can be a barrier, including homeowners, contractors, and even some engineers, resulting in a non-optimal heat pump sizing and selection. While simpler tools exist (RETScreen, HOT2000), they still require minimum modelling knowledge. Additionally, these tools often use monthly average data to estimate the performance of ASHP, which tends to poorly capture the impact of sizing and part load performance. To drive further system adoption, new tools are needed that can accurately estimate ASHP performance while remaining accessible to users with limited technical knowledge.This paper presents the development of a novel simulation tool designed to simplify the selection and performance analysis of ASHPs in single-family Canadian homes. The tool leverages the capabilities of TRNSYS and enhances usability through an intuitive interface. It employs Type 660 models, which use a resistance-capacitance approach to building modelling, to provide a more computationally efficient approach vs. detailed TRNSYS building models (e.g, Type 56). To ensure accuracy, these simplified models were validated against detailed Type 56 models by comparing their energy consumption and zone temperatures at hourly and annual scales. Using Type 660 allows for faster simulation while also allowing users to easily modify the building geometry and envelope. This provides a basis to simulate a wide range of homes with minimal adjustments to key inputs.The tool outputs detailed results on annual building energy consumption and evaluates various heat pump capacities, providing information on the savings potential of properly sized ASHP. Several case studies are presented to compare the performance of the developed tool with detailed TRNSYS simulations, and showcase its potential as a decision support for Canadian homeowners and interested stakeholders.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,002 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».