MétaCan
Menu
Retour à la cohorte
Enregistrement W4416791286 · doi:10.1002/14651858.cd013705.pub4

Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection

2025· article· en· W4416791286 sur OpenAlexaff
Jacqueline Dinnes, Sarah Berhane, Jennifer Walsh, Paul Reidy, Aaron Doherty, Bethany Hillier, Katie Scandrett, D. Hettiarachchi, Fahmida Islam, Yasith Mathangasinghe, Nicholas Nyaaba, Mélissa Taylor, Praveen Weeratunga, Dakshitha Wickramasinghe, Susanna S van Wyk, Jane Cunningham, Clare Davenport, Sabine Dittrich, Devy Emperador, Lotty Hooft, Mariska Leeflang, Matthew D. F. McInnes, René Spijker, Jan Y. Verbakel, Yemisi Takwoingi, Taylor Phillips, Jonathan J Deeks

Notice bibliographique

RevueCochrane Database of Systematic Reviews · 2025
Typearticle
Langueen
DomaineMedicine
ThématiqueSARS-CoV-2 detection and testing
Établissements canadiensUniversity of Ottawa
Organismes subventionnairesDepartment of Health and Social CareNational Institute for Health and Care ResearchBirmingham Biomedical Research CentreUniversity Hospitals Birmingham NHS Foundation TrustWorld Health Organization
Mots-clésAntigenProtocol (science)Confidence intervalMEDLINEClinical trial

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Accurate rapid diagnostic tests for SARS-CoV-2 infection could help manage the COVID-19 pandemic by potentially increasing access to testing and speed detection of infection, as well as informing clinical and public health management decisions to reduce transmission. Previous iterations of this review provided clear and conclusive evidence of superior test performance in those experiencing possible signs and symptoms of Covid-19. However, test performance in asymptomatic individuals and sensitivity by setting and indication for testing remains unclear. This is the fourth iteration of this review, first published in 2020. OBJECTIVES: To assess the diagnostic accuracy of rapid, point-of-care antigen tests (Ag-RDTs) for diagnosis of SARS-CoV-2 infection in asymptomatic population groups. SEARCH METHODS: We searched the COVID-19 Open Access Project living evidence database from the University of Bern (which includes daily updates from MEDLINE and Embase and preprints from medRxiv and bioRxiv) on 17 February 2022. We included independent evaluations from national reference laboratories, FIND and the Diagnostics Global Health website. We did not apply language restrictions. SELECTION CRITERIA: We included test accuracy studies of any design that evaluated commercially produced, rapid antigen tests in asymptomatic people tested because of known or suspected contact with SARS-CoV-2 infection, known SARS-CoV-2 infection or known absence of infection, or those who were being screened for infection. We included evaluations of single applications of a test (one test result reported per person). Reference standards for presence or absence of infection were any laboratory-based molecular test (primarily reverse transcription polymerase chain reaction (RT-PCR)). DATA COLLECTION AND ANALYSIS: We used standard screening procedures with three reviewers. Two reviewers independently carried out quality assessment (using the QUADAS-2 tool) and extracted study results. Other study characteristics were extracted by one review author and checked by a second. We present sensitivity and specificity with 95% confidence intervals (CIs) for each test, and pooled data using the bivariate model. We investigated heterogeneity by including indicator variables in the random-effects logistic regression models. We tabulated results by test manufacturer and compliance with manufacturer instructions for use and according to symptom status. MAIN RESULTS: We included 146 study cohorts (described in 130 study reports). The main results relate to 164 evaluations of single test applications including 144,250 unique samples (7104 with confirmed SARS-CoV-2) obtained from asymptomatic or mainly asymptomatic populations. Studies were mainly conducted in Europe (85/146, 58%), and evaluated 41 different commercial antigen assays (test kit). Only six studies compared two or more brands of test. Nearly all studies (96%) used RT-PCR alone to define presence or absence of infection. Risk of bias was high because of participant selection (13, 9%); interpretation of the index test (3, 2%); weaknesses in the reference standard for absence of infection (3, 2%); and participant flow and timing (46, 32%). Characteristics of participants (11, 8%) and index test delivery (117, 80%) differed from the way in which and in whom the test was intended to be used. Estimates of sensitivity varied considerably between studies, with consistently high specificities. Average sensitivity was 55.0% (95% CI 50.9%, 59.0%) and average specificity was 99.5% (95% CI 99.5%, 99.6%) across the 147 evaluations of Ag-RDTs reporting both sensitivity and specificity (149,251 samples, 7636 cases). Average sensitivity was higher when epidemiological exposure to SARS-CoV-2 was suspected (58.6%, 95% CI 51.4% to 65.5%; 43 evaluations; 15,516 samples, 1483 cases) compared to where COVID-19 testing was reported to be widely available to anyone on presentation for testing (53.0%, 95% CI 48.4% to 57.5%; 103 evaluations; 129,032 samples, 5660 cases); however CIs overlapped, limiting the inference that can be drawn from these data. Average specificity was similarly high for both groups (99.4% and 99.6%). Sensitivity was generally lower when used in a screening context (summary values from 40.6% to 42.1% for three of four screening settings) compared to testing asymptomatic individuals at Covid-19 test centres (56.7%) or emergency departments (54.7%). We observed a decline in summary sensitivities as measures of sample viral load decreased. Sensitivity varied between brands. When tests were used according to manufacturer instructions, average sensitivities by brand ranged from 36.3% to 78.8% in asymptomatic participants (14 assays with sufficient data for pooling). None of the assays met the WHO acceptable performance standard for sensitivity (of 80%) based on meta-analysis; however, sensitivities from individual studies (where meta-analysis was not possible) exceeded 80% for three assays. The WHO acceptable performance criterion of 97% specificity was met by all but four assays (based on individual studies or meta-analysis) when tests were used according to manufacturer instructions. At 0.5% prevalence using summary data for asymptomatic people, where testing was widely available and where epidemiological exposure to COVID-19 was suspected, resulting PPVs would be 40% and 33%, meaning that 3 in 5 or 2 in 3 positive results will be false positives, and between 1 in 2 and 2 in 5 cases will be missed. AUTHORS' CONCLUSIONS: Evidence for antigen testing in asymptomatic cohorts has increased considerably since the publication of the previous update of this review. Average sensitivities remain lower for testing of asymptomatic when compared to symptomatic individuals; however, there is an indication that sensitivities may be higher where epidemiological exposure to SARS-CoV-2 is suspected compared to testing any asymptomatic individual regardless of indication. Sensitivities were particularly low when antigen tests were used in screening settings. Assays from different manufacturers also vary in sensitivity, indicating the need for appropriate clinical validation of a particular antigen test in a given intended use setting prior to more widespread deployment. Further research is needed to evaluate the effectiveness of screening programmes at reducing transmission of infection, whether mass screening or targeted approaches, including schools, healthcare setting and traveller screening. FUNDING: This paper presents independent research supported by the NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust, and the University of Birmingham. The views expressed are those of the author(s) and not necessarily those of the NHS, the NIHR or the Department of Health and Social Care. REGISTRATION: Protocol (2020) doi: 10.1002/14651858.CD013596.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,012
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMétarecherche
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,436
Score d'incertitude au seuil0,996

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,012
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0020,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,131
Tête enseignante GPT0,405
Écart entre enseignants0,274 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeRevue systématique
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2025
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueCochrane Database of Systematic ReviewsMême sujetSARS-CoV-2 detection and testingTravaux en français237 207