Management of acute coronary syndrome and surgical revascularization in a patient with severe Hemophilia A on emicizumab
Notice bibliographique
Résumé
Abstract Patients with Hemophilia A (HA) have been observed to have lower rates of cardiovascular mortality compared to the general population due to a lifelong hypocoagulable state and shorter life expectancy. However, as therapeutic options and life expectancy for these patients have improved, increased rates of cardiovascular diseases, including acute coronary syndrome (ACS), have been noted. This poses a unique challenge as the foundation of ACS management relies on antithrombotic therapies and invasive procedures which necessitate high-dose anticoagulation. Emicizumab, a bispecific antibody that mimics the function of activated Factor VIII (FVIII), further complicates matters due to its interference with common laboratory assays including partial thromboplastin time (PTT)-based assays and Activated Clotting Time (ACT), the mainstay for anticoagulation monitoring during cardiac bypass surgery. The optimal intra-operative monitoring approach for patients on emicizumab undergoing cardiac bypass surgery is unknown, and has only been described in two previous cases in the literature. We therefore describe the third case of an individual with HA on emicizumab who underwent bypass surgery, including our perioperative FVIII replacement and intra-operative monitoring approach which resulted in a positive patient outcome. A 50-year-old male with severe HA (baseline FVIII activity <1%) treated with q4 week emicizumab for 3.5 months presented to a remote community hospital with chest pain. He is known for hemophilia-associated arthropathy and well-managed HIV. Following an initial diagnosis of non-ST elevation myocardial infarction (MI), he received aspirin and therapeutic enoxaparin with FVIII replacement to mitigate bleeding risk. Shortly afterward, his clinical status deteriorated to an ST elevation MI, necessitating the addition of clopidogrel and use of emergent fibrinolytic therapy with further FVIII replacement to target a trough FVIII activity above 100% in the immediate post-lysis period. The patient was then transferred to a local centre with cardiac catheterization (CC) capability and received pre-treatment with FVIII in case coronary stenting was required. During CC, he was found to have coronary anatomy best suited for revascularization with coronary artery bypass grafting (CABG) and was transferred to a cardiac centre with highly specialized hemophilia management capabilities. In collaboration with all relevant specialists, a perioperative plan was formulated. He received bovine chromogenic guided FVIII replacement, and his perioperative period was uncomplicated. Intraoperatively, he was on bypass for 88 minutes and ACT and anti-Xa levels were monitored approximately every 15 and 30 minutes respectively. ACT remained at target between 600-800 seconds and anti-Xa levels ranged between 5-10 U/mL, correlating well with ACT values. CABG was completed in <4 hours with no bleeding or thrombotic complications. He was discharged home one week later with FVIII prophylaxis until post-operative day 14, and emicizumab. There is minimal data on managing arterial thrombosis in patients with hemophilia, and current practice revolves around factor replacement in conjunction with antithrombotic therapy to minimize bleeding risk. The use of emicizumab complicates management due to its laboratory interference including normalizing the PTT and interfering with one-stage coagulation FVIII assays, necessitating specialized lab monitoring and interpretation using non-human (bovine) reagents. Furthermore, the effect of emicizumab on ACT remains variable, with one in-vitro study describing a modest decrease on ACTs while another in vivo study reported results similar to ours, with no apparent effect on ACT. Alternatively, anti-Xa levels can be monitored when more traditional assays are rendered inaccurate, however, this can be challenging in the intraoperative setting given prolonged turnaround times compared to ACT monitoring. Therefore, a combined monitoring approach involving ACT and anti-Xa levels can be used to ensure appropriate anticoagulation in these patients. This case highlights the complex interplay between HA and ACS, balancing thrombotic and bleeding risks, as well as the nuances of lab monitoring for patients on emicizumab. Early identification of these high-risk patients and transfer to a facility with access to specialized laboratory monitoring and multidisciplinary care are required to optimize patient outcomes.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,002 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,002 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».