Validating the use of a multi-fraction sampler for recovering inhalable and respirable dust mass, and metals in workplace air: Application to welding environments
Notice bibliographique
Résumé
,This study validated the Disposable Respirable Sampler (DRS) as an integrated, multi-fraction sampler for simultaneous measurement of inhalable and respirable aerosol mass and associated metals in occupational welding environments, following ISO 7708 definitions. The DRS consists of a disposable body with polyurethane foam, a PVC chimney, and a 25 mm PVC filter. Gravimetric analysis of the filter represents the respirable fraction, while the foam and chimney combined represent the inhalable fraction. Validation included laboratory gravimetric and chemical testing, followed by field sampling at three welding shops in Prince George, BC. Gravimetric tests in a controlled chamber (25 °C, 50% RH) confirmed mass stability of all components over 3–4 weeks. DRS limits of detection (LOD) and quantification (LOQ) were 22/72 µg (filter), 41/137 µg (foam), and 183/610 µg (capsule), within ISO 15767 criteria. Laboratory validation using certified stainless-steel welding fume (SSWF) reference material at four concentration levels (0.1, 0.5, 1, and 2 × TLV) established strong analytical performance. Analytical recovery values for the chimney + foam component ranged from 91.5–107.3% for Cr, 93.5–102.9% for Fe, 87.7–98.9% for Mn, and 90.6–107.1% for Ni, with method repeatability, expressed as the coefficient of variation (CV) ranged from 1.5% to 6.6%, and intermediate reproducibility between 3.0% and 9.7%, all within acceptable thresholds. Recoveries for the filter fraction ranged from 91.7–103.6% for Cr, 92.2–103.1% for Fe, 90.6–97.3% for Mn, and 91.2– 99.8% for Ni, with method repeatability values between 0.8% and 5.4% and reproducibility between 1.0% and 6.4%, confirming robust analytical precision. Field validation across three welding shops revealed substantial to excellent agreement with reference methods for gravimetric measurements (Concordance Correlation Coefficients: 0.767–0.964). For inhalable dust, DRS performance varied: 114% of reference values at Cariboo (CCC = 0.827), 72.6% at GAP (CCC = 0.287), and 97.6% at Stinger (CCC = 0.964), with a pooled mean of 91.5%. Respirable dust results were more consistent, with DRS measuring 0.156, 0.68, and 0.374 mg/m³ versus cyclone values of 0.13, 0.594, and 0.334 mg/m³, reflecting a pooled 15.8% oversampling bias that was consistent and predictable across all sites. Metals analysis showed no statistically significant differences between samplers (p > 0.05) for either fraction, with high correlation coefficients (R² ≥ 0.90) for iron, manganese, copper, and zinc, indicating that gravimetric discrepancies were not due to collection efficiency. This validation confirms the DRS as a reliable, field-ready tool for dual-fraction aerosol sampling in occupational welding environments. The sampler demonstrates minimal capsule wall deposition (
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».