A study of model predictive control strategies for buildings with mixed-mode cooling
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
As awareness about the energy consumption and environmental impact of buildings grows, high-performance building designs that could directly benefit from the advancement of control strategies are gaining significant attention. Building technologies such as thermally activated building systems, thermal storage, mixed-mode cooling systems, etc., take advantage of unique building and weather characteristics such as local heat sources/sinks, and dynamic effects related to variability in occupancy and environmental conditions. Within this context, mixed-mode (MM) cooling is a hybrid approach for space conditioning, employing natural ventilation, where the flow is driven by wind or thermal buoyancy forces sometimes assisted by a fan, and mechanical systems, along with smart switching to minimize building energy use and maintain occupant thermal comfort. However, the control strategies used in current practice usually involve a series of simple heuristics, which may lead to increased operating costs or occupant discomfort since they are not optimized for the local climate and specific building design. Model-based predictive control (MPC) is a promising alternative, particularly suitable for slow response dynamic systems, such as MM buildings with high levels of exposed thermal mass. It solves and implements a sequence of optimal control problems, within a future time horizon, with the most up-to-date information on inputs and environmental disturbances for the dynamic system. The overall objective of this research is to (a) develop control-oriented dynamic models of buildings with high performance mixed-mode features, both time-variant and time-invariant, based on first principles (forward) as well as gray- and black-box system identification that capture the relevant MM building dynamics and mode switching behavior and are computationally efficient for subsequent use in control operations; (b) develop an efficient optimization approach suitable for binary control variables; (c) formulate offline and real-time deterministic MPC prototypes and demonstrate their performance bounds in terms of energy consumption and comfort maintenance in multi-zone MM buildings. To this end, the study developed a detailed dynamic model of a multi-zone building optimally designed for natural ventilation, with high levels of exposed thermal mass and an atrium that assists buoyancy-driven flows, using the finite difference method and integrating the thermal dynamics with a multi-zone airflow network model. The model is then used within an offline deterministic MPC with Particle Swarm Optimization (PSO) as optimizer. Performance bounds (energy consumption and thermal comfort) of predictive controllers are evaluated in comparison with heuristic and baseline night setback control. The results show that MPC can significantly reduce the cooling requirements compared to baseline night setback control while maintaining the operative temperature during the occupied period within acceptable limits. On the contrary, the heuristic control strategies for cooling mode switching, based on simple heuristics for the outdoor conditions, create an increased risk of overcooling with lower thermal comfort acceptability. The optimal control sequences with MPC strategy demonstrate intelligent mode switching with superior overall performance. Results also show that the coordinated control shading devices can further increase the energy savings. The study then extends the physical-based detailed model to forward linear time-variant state-space (LTV-SS) model which provides clarity and insight about the dynamics of MM building operation. The LTV-SS model is validated using measured data from a test-building with mixed-mode cooling under different operational modes, located at Purdue's Architectural Engineering Labs. The validated LTV-SS model is further reduced to a 4th-order model by retaining two states for each controlled zone, representing the air temperature of the zone and the area-weighted mean internal surface temperature. A key feature of the model is the time-variant thermal resistances, which are calculated using an airflow network model. The low-order model can predict the building thermal dynamics with a root mean square error (RMSE) of 0.58 °C for the air and 1.08 °C for the area-weighted mean surface temperature in the south direct gain zone (mode 2). Further on, with the detailed forward LTV-SS model simulation results as training dataset, a linear time-invariant state-space model (LTI-SS) is developed with the subspace identification algorithm. The LTI-SS model can capture the switching behavior of a real multi-zone MM building with high performance features, with RMSE for the air temperature of 0.64 °C, and it is computationally efficient for implementation in real controllers due to its independence on airflow network. An efficient optimization approach is then developed for MM buildings that can be implemented for the binary control of window opening schedules for mode switching. It is based on multi-level optimization topology with progressive refinement and branch-and-bound decision trimming strategy, combined with an effective method for the decision space reduction using heuristic rules. The predictive control with the optimization method show the same performance, in terms of energy savings and thermal comfort maintenance, with the PSO optimization method with significantly lower computing resources (e.g. reduced a 48 hours optimization to 2 hours). Finally, the developed optimization and modeling approaches, are used for formulating a real-time MPC framework, in which a solar prediction model and state initialization method are also proposed. The formulated control framework is implemented and demonstrated in a test-building with MM cooling at Purdue's Architectural Engineering Labs. In summary, the mixed-mode cooling strategies developed in the present study, with the improved predictive control can result in significant reduction of building energy consumption and improvement of occupant comfort. A five-month simulation study for a test-building located in West Lafayette, IN showed 40.7% energy savings when switching schedules are made based on heuristics and 31.0% when a predictive control strategy is used. However, the heuristic strategy would lead to a total exceedance of operative temperature from desired range of 459.7 °C-hr while the corresponding number for the predictive strategy was 45.2 °C-hr. A similar two-month simulation study for a generic section of a building located in Montreal, Canada showed 54.1% savings with heuristic and 38.6% with predictive control with total operative temperature exceedance of 235 °C-hr and 35 °C-hr respectively. The control-oriented modeling approaches, efficient optimization algorithms, and prototypes (numerical and experimental) of predictive control strategies developed in this study facilitate future implementation of MPC strategies in real MM buildings and contribute to the adoption of innovative energy management concepts in engineering practice.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle