MétaCan
Menu
Retour à la cohorte
Enregistrement W6932020888 · doi:10.5683/sp3/jwf7k2

Replication Data for: Large-scale methane controlled release study

2024· dataset· en· W6932020888 sur OpenAlexaffabout

Notice bibliographique

RevueBorealis · 2024
Typedataset
Langueen
DomaineDecision Sciences
ThématiqueProbabilistic and Robust Engineering Design
Établissements canadiensSt. Francis Xavier University
Organismes subventionnairesnon disponible
Mots-clésMethaneTransectMixing ratioWind directionLandfill gasWind speedHydrology (agriculture)Metadata

Résumé

récupéré en direct d'OpenAlex

This publication contains data related to a large-scale methane controlled release study for the purpose of evaluating methane measurement systems for use at landfills. The work was conducted at a closed landfill in Petrolia by FluxLab between November 6th and November 14th, 2023, during 71 different release experiments. A complete report on the study is available on the study sponsor’s webpage: https://erefdn.org/product/a-controlled-release-experiment-for-investigating-methane-measurement-performance-at-landfills/ This data repository provides an archive of release rates, release locations, downwind mixing ratio measurements where available, and meteorological data from onsite and a nearby station. The data repository can be used by the measurement community to validate landfill emission simulations, or for other work. This landfill has an excellent collection system, but minor emissions are present at points totalling about 24 kg/hr, mostly from outside of the area that was used to evaluate the measurement systems. Details on background emissions and quantification can be found in the report cited above. The data is organized into two folders: 1. Measured_data which contains: • Time series of meteorological at three locations of the site (map of locations and metadata is included) • Time series of meteorological data from the closest federal Environment Climate Change Canada (ECCC) meteorological station (metadata is included) • Time series of methane mixing ratio measurements at three locations of the site (map of locations same as meteorological stations) • Time series for downwind off-site transects collected using a mobile lab, including geolocated mixing ratios of methane and carbon dioxide, wind speed, and wind direction 2. Release_data • Source flow rates for each of the 71 experiments • Source locations within the landfill site 3. Rscripts Most of the scoring for participating measurement methods were completed using spreadsheets. However, scripts for generating some of the figures in Hossain et al. (2025) are available in this data set. For mobile measurements we equipped a research vehicle with a Los Gatos Research UGGA gas analyzer (LGR_UGGA) to measure methane and carbon dioxide at 1-2 Hz. There was a mast on top of the truck that housed environmental and positional sensors, including a gas inlet at 2.5-2.7 meters from the ground, a Gill ultrasonic anemometer for measuring wind speed and direction data, a digital compass, and a high-accuracy GPS unit for the campaign. All sensor data was logged using a CR1000X Campbell Scientific data logger. We calibrated the compass daily by driving in four cardinal directions—north, south, east, and west. On a daily basis we tested analyzer's performance using compressed air cylinders of known concentration. We also performed more rigorous multi-point assessments to validate analyzer comparisons before and after the campaign, traceable gas standards. Before each daily survey, we also performed breath tests at the gas inlet to measure and account for the time lag caused by the pump, tubing, and analyzer delay between the inlet and the analyzer. To sample the complete crosswind section of the plume, we drove slowly (~15–20 km hr-1) from the ambient toward the elevated CH4 concentration and returned to the ambient. Access to public roads was typically the limiting constraint for the quantity and placement of off-site transects. Onsite meteorological measurements including windspeed, wind direction, barometric pressure, were collected and later sent to vendors. Campbell Scientific weather sensors (MetSens200 and MetSens500) were used for all onsite meteorological measurements, which were purchased new for the project and deployed with fresh factory calibrations and instantaneous measurements were logged to a Campbell Scientific CR6 datalogger. The MetSens sensors were installed at a height of 2 m. Along with each MetSens we also recorded methane mixing ratios using a small Axetris LGD TDLS sensor, which were calibrated prior to the field deployment using traceable gas standards. Since other activities were of higher priority, we did not benchmark these methane sensors on a daily basis with gases of known concentration. For the controlled releases we used natural gas with composition of 94.5% methane, 4.5% ethane, 0.09% propane, 0.4 % nitrogen, and 0.4 % carbon dioxide, was used for the study. We used ten release points spread over 8 hectares (20 acres), or roughly one-third of the total landfill footprint. Flow controllers logged total flow rate. Alicat flow controllers were used at 10 locations, purchased new and with fresh factory calibrations. Flowmeters have an uncertainty of 0.6%. Total volumetric flowrate data from flow controllers was compared with the end-of-day gas use report from the gas supply and pressure reduction system. All flow rates are reported in this archive as total volumetric rate, without factoring gas composition as we did in the report. This project was funded by Environmental Research and Education Foundation, and National Resources Canada.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,012
score de la tête « metaresearch » (Gemma)0,029
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMétarecherche, Méta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: Sans objet
GenreSignal candidat: Jeu de données · Signal consensuel: Jeu de données
Score de désaccord entre enseignants0,028
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0120,029
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0040,001
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,124
Tête enseignante GPT0,399
Écart entre enseignants0,275 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeSans objet
Domainenon disponible
GenreJeu de données

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2024
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueBorealisMême sujetProbabilistic and Robust Engineering DesignTravaux en français237 207