Using Dynamic Thermal Rating of HVDC Transmission Corridors to Increase Penetration of Renewable Energy
Notice bibliographique
Résumé
As the world shifts its focus toward achieving net-zero emissions, every contributor to greenhouse gas emissions, including the electricity industry, is transitioning to eco-friendly solutions such as renewable generation. Simultaneously, the significant increase in electrical consumption has also highlighted the need to increase the capacity of the transmission infrastructure. As a result, much attention has been paid to the large-scale use of renewable energy through high-voltage direct current (HVDC) transmission technology, ascribing to its economic feasibility. The growing demand for electricity and the increasing penetration of renewable energy sources has prompted the electric power industry to explore methods to optimize the use of existing grid infrastructure. Dynamic Thermal Line Rating (DTLR) is one of the promising techniques that allow transmission lines to operate close to their actual maximum capacity considering real-time operating conditions such as conductor temperature, sag, tension, and weather parameters. Numerous practical implementations and studies on this subject have been carried out thus far starting from the period before World War 2. However, the majority of existing research on this topic has been limited to employing DTLR in classical alternating current based power systems. To this end, this study presents a novel approach by employing DTLR for an HVDC transmission system to maximize the utilization of the transmission capacity and to improve the penetration of renewable energy. This approach can allow the transmission utility companies to expand their utilization of renewable energy integration to the generation mix while reducing or even avoiding capital investments into new transmission line infrastructure. The feasibility and performance of the proposed approach are evaluated by conducting a case study for an HVDC transmission line in Alberta, Canada. The study results find that, on average, the mean increase in HVDC line conductor ampacity rating above the static rating is 64% during winter and 34% during summer. This additional capacity is proposed to integrate wind energy, replacing coal-fired energy generation. This would lead to a significant reduction in greenhouse gas emissions, especially a 13.78 tons per hour reduction in carbon dioxide (CO2). Furthermore, the financial benefits comparison indicates an additional benefit of CA$ 0.10 M/GWh when using DTLR for enhancing the transmission capacity rather than the conventional line upgrading method. Ultimately, this study offers a practical approach to reducing greenhouse gas emissions by integrating more renewable energy resources into the generation mix and reducing curtailment. Furthermore, looking into the global scale, since the long distance transmission from HVDC is gaining more popularity, this will allow the utility companies to optimally choose the best locations where renewable sources are available even though they are either offshore or far away from the load centers.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».