Samsung INR21700 30T 3Ah Li-ion Battery Data
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
The included tests were performed at McMaster University in Hamilton, Ontario, Canada by Dr. Phillip Kollmeyer (phillip.kollmeyer@gmail.com). If this data is utilized for any purpose, it should be appropriately referenced. See the Readme file for more details. A new 3Ah Samsung 3.0T cell was tested in an 8 cu.ft. thermal chamber with a 75amp, 5 volt Digatron Firing Circuits Universal Battery Tester channel with a voltage and current accuracy of 0.1% of full scale. /*************************************************/ A series of tests were performed at six different temperatures, and the battery was charged after each test at 1C rate to 4.2V, 10mA cut off charge current, at battery temperature of 25degC The tests were performed as follows: 1. Four pulse discharge HPPC test (1, 2, 6, and 12C discharge and 0.5, 1, 2, and 4C charge, with reduced values at lower temperatures) performed at 100, 95, 90, 80, 70..., 20, 15, 10, 5, 2.5 % SOC. ("..._HPPC.mat") 2. C/20 Discharge and Charge test. ("..._C20DisCh.mat") 3.0.5C ("..._Dis_0p5C.mat"), 2C ("..._Dis_2C.mat"), and two 1C ("..._Cap_1C.mat") discharge tests. The first 1C discharge test is performed before the UDDS cycle, and the second is performed before the Mix3 cycle. 4.Series of four drive cycles performed, in following order: UDDS(..._UDDS.mat), HWFET(..._HWFET.mat), LA92 (..._LA92.mat), US06 (..._US06.mat). 5. A series of eight drive cycles (mix 1-8) (..._Mixed#.mat) consist of random mix of UDDS, HWFET, LA92, US06. The drive cycle power profile is calculated for a single Turnigy cell in a compact electric vehicle. 6. The previous tests are repeated for ambient temperatures of 40degC, 25degC, 10degC, 0degC, -10degC, and -20degC, in that order. For tests with ambient temperature below 10degC, a reduced regen current limit is set to prevent premature aging of the cells. The drive cycle power profiles are repeated until 95% of the 1C discharge capacity at the respective temperature has been discharged from the cell 7. A series of 16 charges (charge 1-16) (..._Charge##.mat) store the cell charging before and after every drive cycle starting with an inital top up before doing the Cap_1C test /*************************************************/ Matlab (.mat) file naming convention: The file names begin with the date the test started, and are followed by the time the test started and a descriptive name, such as in the following example: "11-07-19_10.49 557_Cap_1C_40degC_IN21700_30T.mat? Date: "11-07-19" (November 7th, 2019) Time: "10.49" (10:49 am) Descriptor: "40degC_IN21700_30T" The naming convention allows for sorting by date and test time when all the files are placed in one folder. This may be useful when trying to determine which charge is associated with which drive cycle, for example, or when looking at aging.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,002 |
| Méta-épidémiologie (sens large) | 0,002 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,003 |
| Science ouverte | 0,033 | 0,055 |
| Intégrité de la recherche | 0,001 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,352 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle