Dataset related to the publication "Temporal dynamics and environmental controls of carbon dioxide and methane fluxes measured by the eddy covariance method over a boreal river"
Notice bibliographique
Résumé
Summary Dataset related to the publication "Temporal dynamics and environmental controls of carbon dioxide and methane fluxes measured by the eddy covariance method over a boreal river" by Aki Vähä, Timo Vesala, Sofya Guseva, Anders Lindroth, Andreas Lorke, Sally MacIntyre, and Ivan Mammarella (2024), published in Biogeosciences. Materials and Methods Measurement site The experiment was conducted on a floating platform on the River Kitinen in northern Finland. The measurements took place from 1 June to 2 October, 2018. The River Kitinen is 235 km long and has a catchment area of 7672 km2. The catchment area consists mostly of managed boreal forest with Scots pine (Pinus sylvestris) and Norway spruce (Picea abies) as the main tree species, wetlands of which a large portion is drained, small streams and rivers, some low mountains and a few small settlements. The experiment site (67.37◦ N, 26.62◦ E, 173 m above sea level) was located next to the Finnish Meteorological Institute’s research and weather station in Tähtelä. At the experiment location the river is 180 m wide and forms a straight section extending approximately 600 m upstream and 1000 m downstream from the site. The direction of the river at the site is roughly north-northwest–south-southeast and it flows towards the south. The mean annual discharge, measured at the closest power plant downstream, is 103 m3 s−1. The maximum depth at the site is 7 m. The River Kitinen’s Strahler stream order at the site is 5. The floating platform was located about 70 m from the eastern river bank where the water depth was 4.5 m. Eddy covariance The eddy covariance system measuring water-atmosphere turbulent fluxes was mounted on a mast on the southern side of the platform. This installation consisted of an ultrasonic anemometer (uSonic-3 Scientific, METEK Meteorologische Messtechnik GmbH, Elmshorn, Germany) for measuring the wind speed in three Cartesian coordinates and the sonic temperature, an enclosed-path gas analyser (LI-7200RS, LI-COR Biosciences, Inc., Lincoln, Nebraska, USA) for measuring carbon dioxide and water vapour mole fractions, and a closed-path gas analyser (G1301-f, Picarro, Inc., Santa Clara, California, USA) for measuring methane and water vapour mole fractions. The centre of the sonic anemometer was 1.82 m above the water surface. An inclinometer (DOG2 micro-electro-mechanical system, Measurement Specialties, Inc., Hampton, Virginia, USA) was used for measuring the pitch and roll of the platform. Eddy covariance fluxes were calculated using the EddyUH software (Mammarella et al. 2016), following the state of art methodologies (Sabbatini et al. 2018, Nemitz et al. 2018). Auxiliary measurements Ambient air temperature and relative humidity were measured with a Rotronic HC2-S3C03 probe (Rotronic AG, Bassersdorf, Germany), mounted inside a Young model 41003 (R. M. Young Company, Traverse City, Michigan, USA) multi-plate radiation shield on the platform’s north-eastern corner. Air temperature and relative humidity were available only after 15th of June. Before that, the sonic temperature and humidity calculated from χH2O, measured with the LI-7200RS, were used instead. Atmospheric pressure and precipitation were measured at the Tähtelä weather station. Photosynthetically active radiation (PAR) in water was measured with two LI-192 sensors (LI-COR Biosciences, Inc., Lincoln, Nebraska, USA) and one LI-193 sensor (LI-COR). The sensors were hanging from wires at 0.3 m, 0.65 m and 1.0 m depths on a beam on the southern side of the platform. Measurements of water side CO2 partial pressure (pCO2) were done by using an off-axis integrated cavity output spectrometer (Ultraportable Greenhouse Gas Analyzer – UGGA), Los Gatos Research, Inc., Santa Clara, California, USA) that was connected to the headspace of an equilibrator consisting of a floating Plexiglas chamber. A water temperature chain was set up 100 m upstream of the platform. It consisted of five temperature loggers of the type RBR Solo (RBR Ltd. Ottawa, Ontario, Canada). The loggers were placed on a taut line mooring at depths of 0.35 m, 1.35 m, 2.35 m, 3.35 m and 4.35 m (6 June to 17 June) and 0.07 m, 1.05 m, 2.05 m, 3.05 m and 4.05 m (17 June onwards). The topmost measurement was used as the surface temperature. The water flow velocity was measured with a acoustic Doppler velocimeter (Nortek Vector, Nortek AS, Rud, Norway) which was installed on a beam on the north-western corner of the platform, facing down (Guseva et al., 2021). The depth of the measurements was 0.4 m below the surface.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,007 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,000 |
| Méta-épidémiologie (sens large) | 0,002 | 0,001 |
| Bibliométrie | 0,003 | 0,006 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,002 | 0,001 |
| Science ouverte | 0,002 | 0,002 |
| Intégrité de la recherche | 0,002 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,082 | 0,046 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».