Engineering performance of rooftop gardens through field evaluation
Notice bibliographique
Résumé
Rooftop gardens or green roofs have the potential to reduce urban heat island and storm water runoff. They can also increase membrane durability, provide green space in urban area, and improve property value. Although green roofs represent an inexpensive adaptation strategy for urban area, technical information on the benefits and durability, in a Canadian context, is not available. To address these issues, the National Research Council of Canada (NRC), in collaboration with members of the North American roofing industry, has initiated a research project in 2000 to provide such information. The main objective of this study is to evaluate the engineering performance of green roofs through field study. NRC has constructed an experimental facility, the Field Roof Facility (FRF), in its Ottawa campus in 2000. This provided an experimental roof area of about 72 m2 (800 ft2). The roof is divided in two equal areas by a 1-m (3-ft) median divider: on one a generic green roof was installed and on the other a conventional roofing assembly with modified bituminous membrane was installed as a reference roof. Both roof sections were instrumented to monitor temperature profile, heat flow, solar reflectance, relative humidity, soil moisture content and storm water runoff. This setup allows direct comparison of the performance and benefits of the Green Roof and the Reference Roof. Observations from the FRF showed that a generic extensive green roof with 150 mm (6 in.) of growing medium could reduce the temperature and the daily temperature fluctuation experienced by the roof membrane significantly in the warmer months. While the exposed roof membrane on the Reference Roof was recorded to reach over 70°C (158°F) in the summer, the membrane underneath the Green Roof reached about 30°C (86°F). In spring and summer, the median daily temperature fluctuation of the membrane was reduced from 42-47°C (76-85°F) on the Reference Roof to 5-7°C (9-11°F) under the Green Roof. The Green Roof also significantly moderated the heat flow through the roofing system and reduced the average daily energy demand for space conditioning due to the heat flow through the roof in the summer by more than 75%. The Green Roof was shown to delay stormwater runoff and reduce peak runoff rate and volume. It retained 245 mm (9.64 in.) out of the 450 mm (17.72 in.) of rain fell during April to September 2002 - a reduction of 54%.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».