Thermodynamic analysis of a direct air carbon capture plant with directions for energy efficiency improvements
Notice bibliographique
Résumé
According to the Intergovernmental Panel on Climate Change, Carbon Dioxide Removal (CDR) technologies play a significant role in deep mitigation pathways to limit global temperature rise to 1.5°C. As a result, interest in them is becoming increasingly prevalent, the most widely discussed being Direct Air Capture (DAC), or active removal of carbon dioxide from atmospheric air. While DAC processes have indeed been successfully tested, one of the most prominent being that developed by Canadian company Carbon Engineering, their widespread deployment faces significant headwinds due to prohibitively high energy consumption and its associated costs. Before DAC can be considered to exist in a state of technological readiness, reductions to the installations' energy demand must be realized. This thesis analyzes the thermodynamic behavior of Carbon Engineering's proposed 1 Mt-CO2/year natural gas fuelled DAC plant, which they describe as “a low-risk starting point rather than a fully optimized least-cost design” [Keith et al., Joule 2, 1573], with the aim to illustrate key areas to which energy efficiency improvement measures must target. With an understanding built of the mechanisms by which energy is utilized and irreversibly lost within their plant, suggestions are put forth for directions to pursue for process improvements, with further analysis included on potential alternative plant configurations which would reduce overall heat and power consumption. A thermodynamic work loss analysis is performed on their plant design at a system level, which finds 92.2% of incoming exergy being lost to thermodynamic irreversibilities. A component-level analysis is then performed to detail the mechanisms by which these losses occur in the most energy-intensive plant segments, namely, the calciner and preheat cyclones, air separation unit, water knockout system, CO2 compression system, and power island. The dissipation of chemical exergy in the air contactor component, i.e., the release of stored chemical exergy as low-grade heat to the environment due to the exothermic reaction of CO2 and aqueous KOH, was determined as the largest unavoidable source of work loss. The most avoidable losses were found to be associated with use of natural gas as a feedstock for heat and power, namely, through its introduction of additional CO2 and water to be processed within the plant, and due to gas turbine power production's inherent Carnot efficiency limits. Additional analysis and discussion follows regarding possible loss reduction measures and modifications, the key concept presented being the use of renewable energy to provide plant power, combined with a calciner using electric resistance heating to meet its reduced thermal demand. Use of a readily-available high-temperature heat source for calciner heat is also considered, with thorough description included of its thermodynamic advantages. Finally, the all-electric plant concept is analyzed at a system level, and its advantages compared to the original natural gas fuelled case.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,007 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».