Direct measurement of sulphur isotope composition in lichens by continuous flow-isotope ratio mass spectrometry (CF-IRMS)
Notice bibliographique
Résumé
An on-line analytical method has been developed for the routine measurement of S isotopic composition in lichens using continuous flow-isotope ratio mass spectrometry (CF-IRMS). 15 mg (equivalent to about 9 μg S) of chemically-untreated lichen powder (Alectoria sarmentosa) together with V2O5 was weighed into 40 mg Sn capsules and then combusted directly in an oxidation-reduction reactor (packed with WO3, pure Cu and quartz wool, heated to 1050°C) of an elemental analyzer, connected to the IRMS via an open-split interface. All combusted gases were carried in a stream of He gas (at 80 mL/min) through a trap (75% Mg(CIO4)2 + 25% quartz chips) to remove H2O(g). A 1.2 m Teflon column (Poropak™ QS, heated to 75 °C) was used to chromatographically separate SO2 from CO2 and N2. The separated gases were transferred into the IRMS through the interface where excess CO2 was diluted by the supply of He (set at 25 psi). Using these parameters over 150 samples can be analyzed successively, changing the H2O trap and cleaning residual ash from the combustion reactor after every 40 samples. -- Mean δ34SCDT values of +6.3 ± 0.4 0/00 (calibrated using sulphates) and +6.1 ± 0.3 0/00 (calibrated using sulphides) measured on a homogenized, composite lichen sample collected from the Botanical Garden of Memorial University of Newfoundland, show excellent agreement with those acquired by dual inlet (DI)-IRMS (+6.2 ± 0.2 0/00), and by on-line CF-IRMS in which samples are chemically pretreated to convert S to BaSO4 (+5.9 ± 0.3 0/00). Four different lichen samples with various S concentrations and δ34S values collected from various locations in Newfoundland also show excellent accuracy and precision compared to DI technique. Lichen samples containing as little as 5-6 μg S (equivalent to about 9 mg lichen powder) produce valid isotopic measurements without a loss of precision. No memory effects were observed over a δ34SCDT value range of +6 to +16 0/00. Compared to DI-IRMS and CF-mineral methods, analytical time and reasonable S amount required per CF-lichen analysis are reduced greatly to 15 mins and 9 μg S, respectively. -- The developed CF-lichen method was applied to young and old portions of single lichen strands (25-35 cm in length) collected from Come-By-Chance oil refinery area, eastern Newfoundland to investigate variations of S isotopic composition with time. There were systematic variations in S isotope signatures (δ34SCDT) between old (+6.2 to +10.9 0/00) and young (+5.1 to +8.2 0/00) portions, suggesting that the old portions may preserve the S isotopic signatures before the refinery operation while those of the young portions show the present S isotopic signatures. This study demonstrates that the micro analytical capability of the developed CF-lichen method can successfully be applied to other studies which require very small amount of organic material with low S concentrations. \n
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».