Comparative Study of the Effects of Physical and Chemical Aging on Extracted and Recovered Asphalt Binders from Some Municipal and Provincial Roads in Canada
Notice bibliographique
Résumé
It has been reported that estimated pavement lifecycles have been reduced by 50-60 % in Ontario over the last 25 years (Auditor General of Ontario, 2016). This raises issues of concern with respect to durability and performance among others. This document aims to comparatively study the effects of physical and chemical aging on the performance of extracted and recovered loose-mix and core mix samples from some provincial and municipal contracts in Ontario. In this study, four loose-mix (plant-aged) and eight core-mix (field-aged, 4 - 5 years) samples were cautiously extracted and recovered using dichloromethane and standard rotary evaporation in a moderate to high vacuum, nitrogen atmosphere and final bath temperature of 160 °C for one hour. The binders recovered from the loose-mix samples were taken through laboratory aging using the standard Superpave® pressure aging vessel method and all the samples were evaluated for their performance using conventional Superpave® methods such as Dynamic Shear Rheometer (DSR) and Bending Beam Rheometer (BBR) and the improved Ministry of Transportation of Ontario methods (LS-308 Extended Bending Beam Rheometer (eBBR) and LS-299 Double-Edge Notched Tension (DENT) test). Chemical test methods like Fourier Transform Infra-red (FTIR) spectroscopy and X-ray Fluorescence (XRF) analysis were used to determine the presence of carbonyls, sulfoxides, zinc and molybdenum which result from chemical oxidation and the addition of recycled engine oil bottoms (REOB). The significant amount of zinc and molybdenum found in all the samples could be a result of addition of REOB, which is known to accelerate the process of physical and chemical aging. All the binders recovered from the loose-mix samples showed better performance based on their performance grading using the dynamic shear rheometer, extended bending beam rheometer and double-edge notched tension test at low, intermediate and high temperatures. Their durability is however suspect since they contained significant amounts of zinc, molybdenum, carbonyls and sulfoxides known to be ‘aging accelerators’. All the field-aged (4-5 yrs.) samples but one showed poor performance at low, intermediate and high temperature which is explained by the comparatively higher amount of zinc, molybdenum, carbonyls and sulfoxides found in them. The extended bending beam rheometer (eBBR) method was seen as a more efficient quality control indicator since some of the samples which passed the regular bending beam rheometer method failed the extended bending beam rheometer test based on the grade losses.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,002 | 0,001 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».