MétaCan
Menu
Retour à la cohorte
Enregistrement W7011883716

A novel methodology assessing the use of Semi-Transparent Photovoltaics integrated onto Double Skin Facades and their impact on the energy consumption of buildings

2023· dissertation· en· W7011883716 sur OpenAlexaboutno aff

Notice bibliographique

RevueSpectrum Research Repository (Concordia University) · 2023
Typedissertation
Langueen
DomaineComputer Science
ThématiqueMobile Agent-Based Network Management
Établissements canadiensnon disponible
Organismes subventionnairesHarvard UniversitySandia National LaboratoriesMassachusetts Institute of Technology
Mots-clésGlazingBuilding-integrated photovoltaicsPhotovoltaicsDaylightingEnergy consumptionSolar gainThermalPhotovoltaic systemSolar energyPassive solar building design
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

Building-integrated Photovoltaics (BIPV) can replace building elements in both facades and roofs improving at the same time the thermal, the electrical and the daylighting performance of the building. A novel approach in BIPV is the Double Skin Façade (DSF) that integrates Semi-Transparent Photovoltaics (STPV). In this approach, the air that passes within the cavity created between the layer of the STPV and the building, acts as a buffer zone and depending on the preferred strategy, it can be used for heating, cooling or ventilating the building. In addition, the STPV is the exterior layer of the envelope, controlling the solar gains but also allowing daylight into the interior space.
\nThis thesis identifies the important parameters of a double skin façade integrating semi-transparent photovoltaics (DSF-STPV) as well as the gaps in the existing literature, namely the lack of experimental studies on mechanically-ventilated DSF-STPV buildings and the lack of investigation of heat transfer coefficients within the cavity in the presence of wind effects. In addition, it appears that there are neither tools to simulate such complex systems nor guidelines to assist architects and engineers to optimally design a DSF-STPV system.
\nA methodology was developed to assess the use of STPV integrated onto DSF and their impact on the energy consumption of buildings. The thermal model employed was verified in an outdoor experimental set-up of a mechanically-ventilated DSF-STPV and an insulating glazing unit (IGU) integrating STPV (IGU-STPV) built at Concordia University (Montreal, Canada). The forced convection within the cavity of the DSF-STPV has been investigated and three Nusselt number correlations were developed and validated. An experimental test-room was also used for a comparison between the DSF-STPV and the IGU-STPV under specific outdoor conditions. From the experimental analysis it has been found that a DSF-STPV can reduce the exterior heat losses due to wind, by more than 20%, whereas the total combined efficiency of the DSF-STPV, can reach the 75% level. The comparison between the DSF-STPV and the IGU-STPV presents increased electrical performance of the DSF-STPV up to 9% and lower average temperature difference that reaches up to 10oC.
\nThe developed Nusselt number correlations were used for the development and validation of a parametric numerical model of a DSF-STPV. The model also allows the user to perform a parametric analysis changing the design parameters of the thermal zone and the DSF-STPV. This model can also simulate battery storage and its effect on peak demand. A parametric analysis was carried out for sixteen (16) different ASHRAE climate zones, two (2) insulation cases for every climate location (baseline and advanced), nine (9) different cavity widths, nine (9) different cavity velocity set-points and twelve (12) different strategies, changing the operation of the DSF-STPV.
\nAn analysis of the optimal operation for all sixteen (16) ASHRAE climate zones was presented, concluding that the climate locations can be separated into three main categories based on their behaviour, i.e. hot and mild, cold, and extreme cold locations, as they present similar patterns and strategies to achieve minimal energy consumption. In addition, the parametric analysis has shown that, for most cases, practical cavity widths under or over 0.50 m - 0.60 m show similar behaviour.
\nThe mismatch between the electricity production by the STPV and the electricity needed for heating and lighting by the adjacent building perimeter zones was investigated, for Montreal, Canada. With the use of a predictive heating strategy, the peak demand of the building can coincide with the peak of the electricity production, resulting in more than 80% reduction in the electricity consumption by the grid during the peak hours.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,174
Score d'incertitude au seuil0,949

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0010,002
Études des sciences et des technologies0,0010,000
Communication savante0,0000,000
Science ouverte0,0020,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,171
Tête enseignante GPT0,352
Écart entre enseignants0,181 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueSpectrum Research Repository (Concordia University)Même sujetMobile Agent-Based Network ManagementTravaux en français237 207