MétaCan
Menu
← Retour à la cohorte
Enregistrement W7024576352

The Sonochemical Extraction of Monazite Using Sulfuric Acid

2023· other· fr· W7024576352 sur OpenAlexfundno aff

Notice bibliographique

RevuePolyPublie (École Polytechnique de Montréal) · 2023
Typeother
Languefr
Domaine
Thématique
Établissements canadiensnon disponible
Organismes subventionnairesPolytechnique Montréal
Mots-clésNucleofectionFilter (signal processing)Work (physics)Limiting
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

RÉSUMÉ: La technique de lixiviation assistée par ultrasons a été utilisée pour extraire les lanthanides (cérium, néodyme, samarium) de la monazite en utilisant de l'acide sulfurique. Les paramètres technologiques tels que le temps de réaction, la concentration en acide, la densité de la pulpe et la température ont été évalués. Les conditions optimales de lixiviation sont les suivantes : H2SO4 à 98 %, puissance ultrasonique de 102 W, rapport liquide-solide de 7:1, température de la matrice à 60 °C et temps de réaction de 30 minutes. Par rapport à la lixiviation silencieuse, les ultrasons ont amélioré les récupérations d'au moins 1,5 fois pour tous les lanthanides étudiés pendant la durée de l'étude. Dans des conditions optimales, la récupération a atteint 31,9 %, 30,7 % et 32,8 % pour le cérium, le néodyme et le lanthane respectivement. Comparativement, les méthodes de lixiviation silencieuses n'ont donné que 21,8 %, 20,8 % et 22,7 %. Les tests ultrasonores ont en outre amélioré les récupérations à 41 % pour les trois terres rares après deux étapes de lixiviation dans des conditions optimales. Les raisons de l'amélioration par ultrasons étaient dues à la cavitation, qui entraînait une augmentation des collisions avec les particules, ainsi qu'à des microjets qui attaquaient la surface des particules, facilitant la rupture des cristaux. En outre, des expériences supplémentaires ont été menées pour comparer des acides inorganiques courants tels que HCl, HNO3 et H2SO4. Des récupérations de terres rares plus élevées ont été obtenues avec HCl et H2SO4, tandis que les résultats avec HNO3 ont été jugés peu fiables en raison de l'érosion de l'alliage monel (cuivre-nickel) utilisé dans le sonotrode. Malgré des améliorations claires dans la récupération des terres rares par rapport aux conditions de lixiviation silencieuse dans cette étude, l'enquête a utilisé jusqu'à huit fois l' H2SO4 utilisé lors des méthodes d'extraction conventionnelles dans l'industrie, et a encore donné des valeurs d'extraction inférieures, par rapport à la récupération de 95 % des terres rares lors des méthodes conventionnelles à haute température dans l'industrie. Toutefois, les tendances de récupération des terres rares au cours de l'étude ont démontré une amélioration claire de l'extraction des terres rares par rapport aux conditions silencieuses et le fait que ces résultats aient été obtenus en seulement 30 minutes et à 60°C indique que l'expansion de la recherche pour analyser la sonication à des températures modérées de 80-90°C et l'optimisation de la conception du réacteur pourrait conduire à des économies d'énergie, de coûts et de temps de réaction par rapport aux méthodes industrielles. ABSTRACT: The ultrasonic-assisted leaching technique was used to extract lanthanides (cerium, neodymium, samarium) from monazite using sulfuric acid. Technological parameters such as reaction time, acid concentration, pulp density, and temperature were evaluated. The optimum leaching conditions were as follows: 98% H2SO4, 102W ultrasound power, 7:1 liquid-to-solid ratio, 60°C matrix temperature and 30 minutes reaction time. In comparison to silent leaching, ultrasound improved recoveries by at least 1.5-fold for all lanthanides investigated for the duration of the study. Under optimal conditions, the recovery reached 31.9%, 30.7% and 32.8% for cerium, neodymium and lanthanum respectively. Comparatively, the silent leaching methods only yielded 21.8%, 20.8% and 22.7%. The ultrasonic testing further improved recoveries to 41% for all three REEs upon two stages of leaching in optimal conditions. The reasons for the improvement by ultrasound were due to cavitation resulting in increased collisions with particles in addition to microjets that attacked the particle surface, facilitating the crystal breakdown. Furthermore, extra experiments were conducted to compare common inorganic acids such as HCl, HNO3 and H2SO4. Higher REE recoveries were achieved with HCl and H2SO4, while the HNO3 results were deemed unreliable due to erosion of the monel (copper-nickel) alloy used in the sono-trode. Despite clear improvements in REE recovery compared to silent leaching conditions in this study, the investigation used up to eight times the H2SO4 used during conventional extraction methods in industry, and still yielded lower extraction values, compared to the 95% REE recovery during conventional high temperature methods in industry. However, the REE recovery trends during the investigation demonstrated a clear improvement in REE extraction over silent conditions and the fact that these were achieved in just 30 minutes and 60°C indicated that expanding the research to analyse sonication under moderate temperatures of 80-90°C and optimizing reactor design could lead to savings in energy, costs, and reaction times when compared with industrial methods.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,001
Score d'incertitude au seuil0,003

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,017
Tête enseignante GPT0,263
Écart entre enseignants0,246 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revuePolyPublie (École Polytechnique de Montréal)→Travaux en français237 207→