Testing of extended shear tab connections subjected to shear
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Shear tab, or single-plate, connections are widely used as simple shear connections in the construction of steel structures. These connections take the form of a single plate shop welded to a supporting column or girder. During erection, the supported beam is moved into place and connected to the shear tab using bolts. In some cases, the eccentricity of the bolt group to the face of the supporting member must be increased due to congestion near the support face or for constructability. In this case, the shear tab connection is considered âextendedâ (the alternative being conventional). The Canadian Institute of Steel Construction (CISC) Handbook of Steel Construction and the American Institute for Steel Construction (AISC) Steel Construction Manual both include pre-designed conventional shear tab connections, the shear resistances of which were computed using the AISC design method [confirmed through testing by Astaneh et al. (1989)]. In addition, the AISC Manual includes a design method for extended configurations.This research aims to verify the accuracy in predicting the shear resistance of extended shear tab connections using a modified method, combining that of CSA S16-09 (2009), the CISC Handbook (2010), and the AISC Manual (2010). The shear resistances of 12 representative shear tab connections were predicted using said method and compared with the measured resistances found through full-scale testing. Four beam-to-column and eight beam-to-girder extended shear tab connections were tested in the Macdonald Engineering Jamieson Structures Laboratory at McGill University. Two of the four beam-to-column tests were governed by flexural tearing of the weld. The welds were sized, as specified in the AISC design method, at 5/8ths of the plate thickness (which assumes 345MPa steel welded with E49 electrodes). This author recommends the welds be sized using a design equation that takes into account the probable yield stress of the steel. The other two beam-to-column tests resulted in plastic local buckling of the bottom edge of the shear tab. The AISC design method allows for the buckling resistance to be calculated using two models: i) lateral torsional buckling or ii) a conservative classical plate buckling. The measured buckling resistances for both tests were significantly better predicted by the latter model. The beam-to-girder tests revealed that two limit states should be accounted for in the design method: i) biaxial buckling of full-height connections, and ii) localized deformation of the supporting girder web and flange for partial-height connections. Design equations are proposed for both of these limit states.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle