Improving apparent inertia, damping, stability, and fault recovery performance in AC power networks with virtual synchronous machines
Notice bibliographique
Résumé
Traditional VSC control is of the “Grid Following Type” (GFL), where the turn-on pulses to the converter switches are determined based on fast synchronization with the external grid voltage phasor. GFL VSC has difficulty operating in very weak ac networks. In contrast, GFM-controlled VSC maintains an internal voltage phasor and has the potential to maintain system stability under such challenging network conditions. One important aspect of VSM type control of a VSC is that it imparts artificial inertia and damping behaviour to the VSC, which can have a significant impact on the VSMs ability to survive frequency events triggered by transient mismatch between generation and loads. This research investigates the disturbance ride through, stability and inertia support of using Virtual Synchronous machine (VSM) Grid-Forming (GFM) control on Voltage-Sourced Converters (VSC) High Voltage direct current (HVdc) transmission system. An adaptive fault ride-through control mode is proposed for VSM to improve its post-fault recovery transient and voltage phase angle jump ride-through performance. The EMT simulation shows the disturbance ride-through performance of VSM GFM with cascaded or switchable current control can be optimized by transiently changing the active power order and the damping coefficient in its power synchronization loop. Linearized models of the VSM with inertia and damping parameters are developed and validated using detailed EMT simulation for system small-signal stability analysis and controller parameter design under different system strengths. A current limiting feature is a necessity in any VSC due to the limited overcurrent ratings of the VSC’s power electronic switches. However, eigenvalue analysis reveals that the VSM can experience instability when connected to strong ac networks with the inclusion of the in-line cascaded current limiting. However, with proper controller tuning, a single suitable gain parameter set can nevertheless be found to allow stable operation under both weak and strong system strength. An important contribution of this research is the development of a novel method for online estimation of system inertia in inverter-based resources (IBRs). A small voltage or current probing signal that is different from the system frequency can be injected into a network to estimate the inertia from the GFM VSCs and synchronous machines. Since the injected signal is very small, the inertia of the GFM IBR can be conveniently measured during the steady-state operation without triggering other transient frequency support control. This can greatly improve the inertia measurement accuracy compared with the more conventional ROCOF observation method.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».