Ten-year field evaluation of corrosion-inhibiting systems in concrete bridges barrier walls
Notice bibliographique
Résumé
The performance of eight commercial corrosion-inhibiting systems was assessed in the field over ten years on reinforced concrete barrier walls of a highway bridge that was subjected to severe environmental conditions. These systems were composed of one or more of the following components: anticorrosion concrete admixtures, reinforcement coatings, and concrete surface coatings/sealers. The field evaluation consisted of annual surveys of corrosion potential and corrosion rate, as well as visual inspections and testing of concrete cores. After ten years, the main reinforcement of the barrier walls, at a depth of 75 mm [3 in.], was found in relatively good condition due to an initially good quality concrete. Special bars embedded at a depth of 13 mm [1/2 in.] in the barrier walls showed signs of advanced corrosion for all systems, however, no visible signs of corrosion were found on 25 mm [1 in.] deep bars. Non-destructive corrosion evaluation over the 25 mm [1 in.] deep ladder rebars indicated that the system containing the inorganic anticorrosion admixture provided consistently lower risks of corrosion, followed by systems containing organic anticorrosion admixtures, in comparison to the control system and other systems. The low concrete permeability and different stability of the protective layer forming on the bars may explain the observed differences in the effectiveness of these systems.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».