Flow-Sound-Structure Interaction in Spring-Loaded Valves
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
This thesis provides a comprehensive investigation of flow-sound-structure coupling in spring-loaded valves subjected to air flow. While they are commonly used in a multitude of applications, these types of valves have been found to experience severe vibrations when interaction is present among the structure, the hydrodynamic field, and the acoustic field for a range of operational valve structural characteristics, flow parameters, and connected piping length. The first part of this investigation was aimed at characterizing experimentally the valve’s dynamic behaviour and the parameters affecting the onset of self-excited instability. The occurrence of instability was mainly driven by the presence of acoustic feedback: the connected length of piping had to be sufficiently long, with a longer pipe correlating to more severe vibrations. In addition, it was found that the valve’s oscillation frequency depends on the modal characteristics of the combined valve piping system, rather than the structural natural frequency alone. Furthermore, an increase in the valve’s spring stiffness caused the vibrations to become more severe. Meanwhile, other parameters such as initial spring preload force and valve plate area only had moderate effects on the stability behaviour of the valve. The second part of the investigation sought to develop a theoretical model that could simulate the valve’s response when subjected to air flow while considering the effects of acoustic feedback and impact on the seat and limiter. Thus, a structural model of the valve was developed based on a single-degree-of-freedom model of the system with impact computed based on a pseudo-force method. The hydrodynamic field relied on a one dimensional unsteady Bernoulli description of the flow. Finally, the acoustic interaction was accounted for using the one-dimensional wave equation resolved using a finite difference scheme. The model has demonstrated remarkable agreement with the experimental results. It has shown an ability to predict the modal characteristics of the system as well as correctly predict the effect of increased stiffness or increased piping length on vibration amplitude. The final part of the investigation consisted in designing countermeasures to mitigate the effects of this self-excited instability mechanism. A concentric Helmholtz-type cavity resonator, an orifice plate, and an anechoic termination are placed at the downstream side of a model valve which were seen to be unstable in the experimental and modelling phases of the investigation. All tested devices were able to eliminate the self excited instability mechanism. The applicability and robustness of each of these methods were discussed.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,096 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle