EFFECT OF VERTICAL GROUND MOTIONS ON SEISMIC ISOLATION DESIGN OF THE CANADIAN PARLIAMENT BUILDING
Notice bibliographique
Résumé
The ongoing restoration of Canada's Parliament Building, a prominent heritage building, includes the implementation of seismic isolation to enhance its seismic resilience. With its 6-story Centre Block featuring stone and brick walls, steel columns, and unreinforced concrete foundations, as well as the vulnerable 92 m tall Peace Tower supported by unreinforced concrete piers, addressing seismic risk is crucial. Approximately 580 isolators, including elastomeric bearings and flat sliding bearings, are utilized in the seismic isolation system to achieve cost-effective retrofitting while preserving the building's heritage characteristics. When complete, it will be one of the largest seismically-isolated heritage buildings in North America. A comprehensive three-dimensional analytical model was utilized to conduct detailed nonlinear time history analyses, accurately capturing significant mass and stiffness irregularities within the structure. Two sets of 11 ground motion records were carefully selected—one scaled for the short-period range of the design response spectrum, representing nearby earthquakes of smaller magnitude, and the other for the long-period range, representing larger magnitude distant earthquakes. A site-specific vertical target response spectrum was developed, and scaling factors for the vertical ground motion component were determined independently to ensure compatibility with the vertical spectrum. This paper focuses on investigating the impact of the vertical component of ground motions on the shear demands of the superstructure walls and piers within the isolated structure. Notably, the results reveal a significant increase in shear demands for the superstructure walls due to the vertical component of short-period ground motions, which may not be effectively attenuated by the isolation system. These additional induced shear demands primarily occur within the frequency range associated with the vertical vibration frequency of individual floors and the global vertical mode linked to the overall vertical stiffness of the isolation system. A comparison of shear demands with and without the vertical component highlights the importance of considering it in the analysis, assessment, and design of seismically-isolated heritage structures. Despite the increased shear demands, the seismic isolation system effectively reduces induced base shear in the walls compared to conventional retrofit methods for fixed base structures.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».