Bioceramic arm garment does not increase diameter of brachial artery and blood flow—Compliance and biceps microcirculation in male recreational sports practitioners at rest: A single blinded randomized cross-over study
Notice bibliographique
Résumé
• Use of a far-infrared (FIR) reflective arm garment for 40-minutes at rest in physically active men did not induce significant effects on brachial artery diameter, carotid–radial pulse wave velocity, tHb, HHb, or O₂Hb and skin temperature. • Under the conditions of our study (i.e., at rest in physically active men), the FIR arm garment are likely ineffective in improving micro- and macrovascular function. • From a practical standpoint, this technology is intended to be used during exercise or recovery. Based on our experimental design, it appears that the FIR arm garment would be ineffective in inducing any vascular benefit at rest if worn for 40 minutes before exercise and during the recovery period, when hemodynamic is stabilized. Interest in clothing that reflects far infrared (FIR) radiation naturally emitted by the body during and after exercise has increased based on the assumption that this can increase arterial and venous blood flow. Indeed, in vitro and animal model research seems to report promising effects of FIR on the nitric oxide pathway and microcirculation. However, to date, there are no well controlled studies investigating the effect of FIR garments on resting microvascular and macrovascular function in humans. Thus, the aim of this study was to examine the acute effects of wearing FIR arm garments on vascular function. Thirty-one male recreational sport practitioners (4.9 ± 3.3 h of sport/week; 32.1 ± 9.5 years; 178.6 ± 7.9 cm; 74.1 ± 11.2 kg; 23.2 ± 2.5 kg/m 2 (mean ± SD)) completed 4 visits: repeatability measurements (2 sessions), placebo, and FIR conditions in random order. Measurements (i.e., without arm garment) of brachial artery diameter and blood flow, carotid-radial pulse wave velocity (CR-PWV), as well as total-, oxy-, and deoxy-hemoglobin were completed after 15 min of rest and repeated after wearing FIR or placebo arm garments for 25 min, 40 min, and 50 min. Two skin sensors were positioned on the upper arm and the forearm to continuously record skin temperature and pressure under the garment. The main results were that at all time points, compared to placebo, FIR did not significantly affect brachial artery diameter and blood flow, CR-PWV, or total hemoglobin (condition × time interaction: p = 0.22, 0.54, 0.51, 0.96, respectively). Moreover, no significant condition × time × sensor position interaction effect was found in skin temperature ( p = 0.99). However, pressure under garment was significantly higher under the FIR condition compared to placebo (+53%, p = 0.01, 95% confidence interval: FIR: 1.64–2.92 mmHg; placebo: 0.88–2.14 mmHg) while microvascular parameters were unchanged. Contrary to our hypothesis, wearing an FIR arm garment at rest does not lead to an improvement of either macro or microvascular function. These results suggest limited benefits in the sports context, notably during recovery.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,002 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».