Relationship between hyperhomocysteinemia and the risk of stroke recurrence:a Meta⁃analysis
Notice bibliographique
Résumé
ObjectiveTo explore the relationship between hyperhomocysteinemia and the risk of stroke recurrence,so as to provide the basis for related clinical decision⁃making.MethodsThe prospective cohort studies on the relationship between hyperhomocysteinemia and the risk of stroke recurrence were retrieved from PubMed,EMbase,The Cochrane Library,Web of Science,Wanfang Data,China Biology Medicine disc(CBM),China National Knowledge Infrastructure(CNKI),and VIP Database from the establishment of the databases to January 31 2020.According to the inclusion and exclusion criteria,two researchers independently screened the literature,extracted the data,used the Newcastle⁃Ottawa scale(NOS)for quality evaluation,and used RevMan5.3 and Stata11.0 software for meta⁃analysis on the data.ResultsA total of 22 prospective cohort studies were included,involving 26 400 patients with stroke.Relationship between hyperhomocysteinemia and the risk of stroke recurrence:adjusted OR values combination showed that hyperhomocysteinemia increased the risk of stroke recurrence[OR=1.27,95%CI(1.10,1.46),P=0.000 9].The combination of unadjusted OR values showed that hyperhomocysteinemia increased the risk of stroke recurrence[OR=1.24,95%CI(1.15,1.33),P<0.000 01].Relationship between hyperhomocysteinemia and the risk of stroke recurrence in different follow⁃up periods:adjusted OR values combination showed that hyperhomocysteinemia increased the risk of stroke recurrence during a follow⁃up period of 1 to 3 years[OR=1.30,95%CI(1.04,1.61),P=0.02];and hyperhomocysteinemia during the follow⁃up period>3 years increased the risk of stroke recurrence[OR=1.21,95%CI(1.02,1.44),P=0.03].The combination of unadjusted OR values showed that hyperhomocysteinemia increased the risk of stroke recurrence during the follow⁃up period of less than 1 year[OR=2.45,95%CI(1.20,4.97),P=0.01];and hyperhomocysteinemia increased the risk of stroke recurrence during a follow⁃up period of 1 to 3 years[OR=1.39,95%CI(1.21,1.58),P<0.000 01];hyperhomocysteinemia increased the risk of stroke recurrence during the follow⁃up period>3 years[OR=1.18,95%CI(1.09,1.27),P<0.000 1].Relationship between hyperhomocysteinemia and the risk of stroke recurrence or different stroke types:the adjusted OR value showed that hyperhomocysteinemia increased the risk of recurrence of large artery atherosclerotic stroke[OR=1.09,95%CI(1.03,1.16),P=0.006];hyperhomocysteinemia did not increase the risk of large artery atherosclerotic stroke[OR=0.69,95%CI(0.31,1.53),P=0.37].The unadjusted OR values combination showed that hyperhomocysteinemia did not increase the risk of recurrence of atherosclerotic stroke in large arteries[OR=1.33,95%CI(0.92,1.92),P=0.12];hyperhomocysteinemia did not increase the risk of recurrence of arteriolar occlusive stroke[OR=1.35,95%CI(0.97,1.87),P=0.07].ConclusionsCurrents evidences showed that hurrent evidence shows that Hyperhomocysteinemia might be a risk factor for stroke recurrence.It was suggested that clinical doctors and nurses should routinely detect the level of hyperhomocysteinemia in stroke management and take effective intervention measures to improve the prognosis of stroke patients.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,013 | 0,020 |
| Méta-épidémiologie (sens strict) | 0,003 | 0,002 |
| Méta-épidémiologie (sens large) | 0,016 | 0,048 |
| Bibliométrie | 0,005 | 0,006 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,004 | 0,001 |
| Science ouverte | 0,002 | 0,001 |
| Intégrité de la recherche | 0,002 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,004 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».