Feasibility of low-cost CO₂ sensors for demand-controlled ventilation-laboratory chamber testing
Notice bibliographique
Résumé
Demand-controlled ventilation (DCV) systems have some advantages over other building ventilation strategies, as they can maintain acceptable indoor air quality (IAQ) of a space while reducing the overall energy consumption of building ventilation. When selecting sensors for DCV, it is important to consider their performance and cost. Over the past several years, there has been an increase in the availability of low-cost sensors. However, the feasibility of using the currently available low-cost sensors within DCV is an area that requires further investigation. The focus of the work presented in this paper is to evaluate the feasibility of current low-cost carbon dioxide (CO₂) sensors for use in DCV using a controlled environment. The performance of three low-cost CO₂ sensor models was verified to determine their suitability in the control ofDCV. Preliminarytesting revealedunacceptable inaccuracy in one of the three sensors. This sensor uses micro-hotplate technology for gas sensing and was excluded from detailed testing. The two sensors tested in detail use nondispersive infrared (NDIR) technology. The accuracy of the first NDIR sensor (model A) was satisfactory; some of the sensor measurements deviated from the dosed concentration by more than 100 ppm, but remained within 150 ppm. The nonlinearity of sensor model A was greater than model B but was acceptable—the maximum deviation from the linear line of best fit ranged between 55 and 92 ppm. The repeatability of sensor model A was acceptable; sensor measurements during the three days of testing were always within 100 ppm when measuring the same CO₂ concentration. In fact, the maximum recorded nonrepeatability was 73 ppm. The hysteresis of sensor model A was satisfactory; most sensor measurements were within 100 ppm and all were within 150 ppm when measuring the same CO₂ concentration when approached from varying directions. However, sensor model A had a tendency to underreport CO₂ concentrations, which could reduce IAQ if the sensors were not calibrated or if the tendency to underreport was not considered in the control algorithm. Sensor model A consistently underreported decreasing CO₂ at a larger magnitude, which would likely cause the DCV system to turn off sooner than desired, potentially negatively impacting IAQ. The accuracy of the second NDIR sensor (model B) was found to be better than model A and was deemed acceptable. The sensor measurements were always within 100 ppm of the dosed concentration. Sensor model B did have a tendency to overreport CO₂ concentrations, which could result in more energy consumption than ideal; however, the impact is expected to be low due to the better accuracy ofthe sensor. The nonlinearity ofsensor model B was satisfactory; the maximum deviation from the linear line of best fitrangedbetween 30and55 ppm. The repeatability ofsensor model B was satisfactory; all but one of the sensor measurements during the three days of testing were within 100 ppm when measuring the same CO₂ concentration. The hysteresis of sensor model B was exceptional; sensor measurements were typically within 20 ppm when measuring the same CO₂ concentration when approached from either high or low concentrations and were always within 60 ppm. Sensor model B was found to be suitable for use in DCV. This work shows that ultra low-cost CO₂ sensors in the area of $27 CAD ($20 USD) each may not be suitable for DCV, but that low-cost CO₂ sensors in the area of $80 CAD ($60 USD) could be suitable for developing a low-cost controller and sensor package for managing indoor CO₂ concentrations.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».