MétaCan
Menu
Retour à la cohorte
Enregistrement W7144182055 · doi:10.24561/00018890

Reliability-based design for buckling strength of stiffened steel plates : ultimate and serviceability limit states

2019· dissertation· en· W7144182055 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

aboutLe titre ou le résumé porte un signal canadien du lexique géographique.
no affAucune affiliation canadienne : ce travail est invisible pour une base fondée sur la seule affiliation.
Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Notice bibliographique

RevueInstitutional Repositories DataBase (IRDB) · 2019
Typedissertation
Langueen
DomaineEngineering
ThématiqueStructural Integrity and Reliability Analysis
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésServiceability (structure)BucklingLimit state designLimit (mathematics)WeldingLimit load

Résumé

récupéré en direct d'OpenAlex

The strengths of longitudinally continuous stiffened steel plates under uniaxial compression were investigated by employing a combination of numerical and probabilistic approaches. The probabilistic compressive strengths were obtained for two different limit states, i.e. the Ultimate Limit State (ULS) and the Serviceability Limit State (SLS). For slender stiffened plates, the SLS is particularly important because large out-of-plane deflection occurs due to elastic buckling, before reaching the ultimate strength. Due to lack of specific criteria to determine the compressive strength at SLS, a rational criterion has been proposed based on elastic buckling strength and fabrication tolerance. Three different stiffened plate models with three, two, and one flat plate longitudinal stiffeners, corresponding to Model-1, Model-2, and Model-3 were considered for the study, where Model-1 and Model-2 shows column-like behavior (small post-buckling strength) and Model-3 exhibits plate-like behavior (significant post-buckling strength reserve). The plates of both normal and high-performance steel (SBHS) were taken into account, and their thickness was varied from 10 to 90 mm. The compressive strengths at ULS and SLS were determined from nonlinear elasto-plastic finite element analysis (FEA), where both material and geometric nonlinearity were taken into account. As a source of variability of the compressive strengths, variation of the initial out-of-plane deflection and residual stress were considered simultaneously in the FEA. The probabilistic distribution of the compressive strengths for Model-1 and Model-2 were obtained through Monte Carlo simulations in association with the response surface method. The response surface function is a second order polynomial of the independent random variables, i.e. the initial out-of-plane deflections and the residual stresses. For Model-3, an approximate estimation procedure was followed to obtain the first-order mean values. The first order variances were also estimated approximately, employing the Taylor series finite difference (TSFD) method. Based on the obtained probabilistic information, partial safety factors were proposed, considering the mean value strengths as the nominal strengths, as an example. The study results were compared with different design codes e.g. JSHB, AASHTO, Eurocode, and Canadian Code. Comparing to the ULS strengths for Model-1 and Model-2 with a 5% non-exceedance probability indicate that the JSHB, AASHTO, and Canadian Code provides significantly conservative design, specifically for stiffened plates with high reduced slenderness parameters. However, in the middle range of reduced slenderness parameters, AASHTO and Canadian Code predicts overestimated strengths for Model-3. All of the three Models showed better agreement with the Eurocode than other design specifications. Nevertheless, a scope for improvement of the Eurocode was addressed by considering continuous stiffened panels (in the longitudinal direction) rather than an isolated panel. The uniqueness of this research is that the effect of thick plates and SBHS steels were included. Furthermore, rather than deterministic strengths, probabilistic strengths are provided for column-like behavior and plate-like behavior, which can be used as an important reference for developing a reliability-based design strength curve.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,001
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Simulation ou modélisation · Signal consensuel: Simulation ou modélisation
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,261
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,001
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,001
Science ouverte0,0000,000
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,015
Tête enseignante GPT0,249
Écart entre enseignants0,234 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle