MétaCan
Menu
← Retour à la cohorte
Enregistrement W7163830101 · doi:10.5281/zenodo.20581438

Climate-Responsive Architecture: Strategies for Sustainable Built Environments

2023· article· en· W7163830101 sur OpenAlexaff
Rupa V Belagali

Notice bibliographique

RevueZenodo (CERN European Organization for Nuclear Research) · 2023
Typearticle
Langueen
DomaineEngineering
ThématiqueBuilding Energy and Comfort Optimization
Établissements canadiensImpact
Organismes subventionnairesnon disponible
Mots-clésContext (archaeology)Urban heat islandUrbanizationBuilt environmentSustainabilitySustainable designPlanetary boundariesClimate changeGlobal warming

Résumé

récupéré en direct d'OpenAlex

Abstract As the global construction sector faces the dual pressures of rapid urbanization and the escalating climate emergency, the necessity for buildings that perform efficiently within their specific climatic context has become paramount. Climate-responsive architecture (CRA) emphasizes the integration of building form, material selection, and site planning to harmonize with the local environment. This article explores the fundamental strategies of CRA, categorizing them into passive design principles, active technological integrations, and site-sensitive approaches. Through a review of current practices, thermodynamic modeling, and comparative case studies, we demonstrate that buildings designed with local meteorological data—specifically solar orientation, wind patterns, and humidity—can drastically reduce reliance on mechanical HVAC systems while enhancing occupant comfort. Furthermore, this research examines the role of policy, the reduction of the Urban Heat Island (UHI) effect, and the potential of adaptive, AI-driven kinetic facades and digital twin technology to facilitate a transition toward resilient, net-zero urban ecosystems. Keywords: Climate-Responsive Architecture, Sustainable Design, Passive Solar, Building Energy Efficiency 1. Introduction The global built environment is responsible for approximately 40% of energy-related carbon emissions, making it a critical frontier in the fight against climate change. Historically, vernacular architecture—the wisdom of regional building traditions—relied on climate-responsive design out of absolute necessity. From the thick, thermal-mass adobe walls of arid climates to the elevated, permeable structures of the humid tropics, these buildings worked in tandem with their environments. With the mid-20th-century advent of inexpensive fossil fuels and the global proliferation of standardized, "international style" glass-box architecture, this localized intelligence was largely abandoned. The result was a generation of buildings disconnected from their surroundings, relying on heavy mechanical "life support" systems for heating, cooling, and ventilation. Climate-responsive architecture (CRA) seeks to reverse this paradigm by re-establishing a symbiotic relationship between building performance and local climate. By treating the building as an "organism"—one that breathes through natural ventilation, regulates its temperature through thermal mass, and shields itself through strategic orientation—architects can minimize energy demands while maximizing occupant well-being. This discipline requires a departure from prescriptive, code-minimum design towards performance-based, context-specific modeling. 2. The Bioclimatic Design Framework Bioclimatic design, as pioneered by Victor Olgyay and later refined by contemporary scholars, posits that architectural comfort is determined by the intersection of human physiological needs and environmental variables. It is the synthesis of meteorology, human biology, and architectural engineering. 2.1. Passive Design Principles: The First Line of Defense Passive design utilizes the building's fabric, volume, and orientation to regulate internal conditions without mechanical intervention. Solar Geometry and Orientation: The fundamental strategy involves orienting the primary building axis to optimize solar exposure. In cold climates, high-thermal-mass floors should be exposed to southern sun to act as heat sinks. In hot climates, facades must be protected by horizontal shading devices or external brise-soleil to block direct radiation while allowing diffuse light. The Thermal Labyrinth: An innovative passive strategy involving underground air tunnels. By pulling intake air through a subterranean labyrinth, the building leverages the earth’s stable deep-ground temperature, pre-cooling air in summer or pre-warming it in winter before it enters the internal spaces. Stack Ventilation and Solar Chimneys: Natural ventilation is not merely about opening windows; it is about creating pressure differentials. The stack effect utilizes vertical temperature gradients—warm air rises and escapes through high-level apertures, pulling cooler, fresher air in from lower-level inlets. A "solar chimney"—a vertical shaft painted black and topped with glass—can accelerate this process by heating air internally to create a powerful updraft. 2.2. Psychrometrics and Human Thermal Comfort Understanding thermal comfort requires mastering psychrometrics—the study of air-water vapor mixtures. The Predicted Mean Vote (PMV) model, developed by Fanger, provides a framework for understanding how air temperature, radiant temperature, humidity, and air velocity interact with human metabolic rates and clothing levels. CRA projects often utilize "Adaptive Comfort Models," which recognize that occupants in naturally ventilated buildings have a higher tolerance for temperature fluctuations than those in sealed, air-conditioned environments, allowing for a wider range of acceptable temperatures and significant energy savings. Beyond mere physical comfort, there is a profound psychological dimension to thermal environments. Lisa Heschong, in Thermal Delight in Architecture, argues that the loss of sensory richness in modern, climate-controlled spaces—where the temperature is uniform and stagnant—leads to a "thermal numbness." By introducing deliberate temperature variations, such as cooler zones near a breeze-way or warmer radiant zones near a sunlit wall, architects can provide a "thermal pleasure" that reconnects occupants to the changing seasons. 2.3. Active Technology Integration While passive strategies form the foundation, high-performance architecture utilizes active systems for precision control: Building Integrated Photovoltaics (BIPV): Solar generation is now an aesthetic and structural component, integrated into facade panels, skylights, and even balcony railings, turning the building into a localized power plant. Electrochromic and Adaptive Glazing: Smart glass that adjusts its tint or opacity based on real-time solar intensity, drastically reducing cooling loads without compromising visual comfort. Heat Recovery Ventilation (HRV): In airtight, highly insulated envelopes, HRV systems extract heat from outgoing stale air and transfer it to incoming fresh air, maintaining indoor air quality with minimal energy loss. Table 1: Climate Strategy by Zone Climate Zone Priority Strategy Building Characteristic Key Material Focus Hot-Dry Cooling & Heat Rejection High thermal mass, small openings Adobe, Rammed Earth, Brick Hot-Humid Ventilation & Dehumidification Elevated structure, large apertures Bamboo, Lightweight timber Cold Insulation & Heat Retention Compact form, triple glazing High-R Aerogels, Vacuum panels Temperate Flexibility Adjustable shading, seasonal ventilation Double-skin facades, smart glass 3. Materiality and the Envelope: The Dynamic Interface The building envelope is no longer a static barrier; it is a dynamic interface mediating between volatile exterior conditions and stable interior needs. Phase Change Materials (PCM): These materials absorb and release latent heat as they transition between solid and liquid phases. When embedded in ceiling tiles or wallboards, PCMs act as an invisible "thermal battery," effectively flattening peak cooling and heating loads. Vertical Forests and Bio-Cladding: Integrating living vegetation into the building skin provides natural shading, evaporative cooling, and significant air filtration. This "biological cladding" also mitigates the UHI effect and restores urban biodiversity. Mass Timber and Carbon Sequestration: Shifting from concrete and steel to cross-laminated timber (CLT) drastically reduces the embodied carbon of a building while providing natural thermal insulation and humidity regulation. Fig.1: Building Performance Workflow 4. The Impact of Urbanization and Thermal Comfort Climate-responsive design exists within the larger context of the urban fabric. The Urban Heat Island (UHI) effect—where cities are significantly warmer than surrounding rural areas due to non-reflective surfaces, limited vegetation, and waste heat—is a major impediment to sustainable urban health. Albedo Management: Replacing dark, heat-absorbing asphalt and roofing with high-albedo (reflective) materials can lower ambient temperatures by several degrees. Urban Wind Corridors: Dense high-rise clusters often trap heat and pollutants. Strategic urban planning must preserve "wind corridors" that allow prevailing breezes to flush through the city, providing a natural cooling effect. The "Right to Cooling": As heatwaves become more frequent, there is an increasing ethical argument for equitable access to climate-responsive design. This "right to cooling" demands that social housing and low-income areas receive the same level of performance-based design as luxury developments. 5. Case Studies in Practice The Edge (Amsterdam): Often cited as the world’s smartest building, its facade is oriented to maximize daylight while minimizing heat gain. Its ceiling-mounted sensor network continuously monitors occupancy, lighting, and climate, adjusting resources only where needed. BedZED (London): A pioneer of mixed-use development, it utilizes passive solar heating, high-thermal-mass construction, and iconic wind-cowls for natural ventilation, proving that community-scale sustainable living is viable. Council House 2 (Melbourne): A benchmark in CRA, this building utilizes chilled ceiling panels and an "auto-facade" that changes its configuration based on the sun’s path, demonstrating the power of kinetic architectural elements. 6. The Future: Digital Twins and Predictive AI The next frontier of CRA is the integration of Digital Twins—virtual replicas of buildings that inge

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,003
score de la tête « metaresearch » (Gemma)0,002
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Théorique ou conceptuel · Signal consensuel: Théorique ou conceptuel
GenreSignal candidat: Empirique · Signal consensuel: aucune
Score de désaccord entre enseignants0,006
Score d'incertitude au seuil0,025

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0030,002
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0020,009
Communication savante0,0060,005
Science ouverte0,0020,006
Intégrité de la recherche0,0030,003
Charge utile insuffisante (le modèle a refusé de juger)0,0060,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,017
Tête enseignante GPT0,218
Écart entre enseignants0,201 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeThéorique ou conceptuel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2023
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueZenodo (CERN European Organization for Nuclear Research)→Même sujetBuilding Energy and Comfort Optimization→Travaux en français237 207→