MétaCan
Menu
Back to cohort
Record W1012347533 · doi:10.1016/j.procs.2015.05.135

An Experimental Study Onthe Dehumidification Performance of a Low-flow Falling-film Liquid Desiccant Air-conditioner

2015· article· en· W1012347533 on OpenAlexafffundabout
S. Bouzenada, Christopher McNevin, Stephen C. Harrison, A. Kaabi

Bibliographic record

VenueProcedia Computer Science · 2015
Typearticle
Languageen
FieldEngineering
TopicAdsorption and Cooling Systems
Canadian institutionsQueen's University
FundersNatural Resources CanadaNatural Sciences and Engineering Research Council of CanadaCanadian Natural Resources Limited
KeywordsDesiccantAir conditioningLiquid desiccantMaterials scienceVolumetric flow rateMoistureHumidityEnvironmental scienceRegenerative heat exchangerAir dryerInletThermodynamicsMechanicsProcess engineeringComposite materialMechanical engineeringHeat exchangerPhysicsEngineering

Abstract

fetched live from OpenAlex

The dehumidifier is one of the main componentsinopen-cycle liquid desiccant air-conditioning systems. An experimental study was carried out to evaluate the performance of asolar thermally driven, low-flow, falling-film, internally-cooledparallel-plate liquid desiccant air-conditioner in Kingston, Ontario at Queen's University. A solution of LiCl and water was used as the desiccant.Unlike high-flow devices, the low-flow of desiccant solution flowing across the unit's dehumidifier and regenerator sections produces large variations in solution concentration. In this study, a series of tests were undertaken to evaluate the performance of the dehumidifier section of the unit. Results presented are based on mass flow and energy transport measurements that allowed the moisture transport rate between the air and liquid desiccant solution to be determined. Based on these results, arelationship between the desiccant concentration and the rate of dehumidification rate was found and the effect of inlet-air humidity onthe dehumidification effectiveness identified. The moisture removal rate of the system was found to range from 1.1 g/s to 3.5 g/s under the conditions evaluated. These result corresponded to an average dehumidification effectivenessof 0.55.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.248
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2015
Admission routes3
Has abstractyes

Explore more

Same venueProcedia Computer ScienceSame topicAdsorption and Cooling SystemsFrench-language works237,207