MétaCan
Menu
← Back to cohort
Record W1038155642 · doi:10.1118/1.4924955

SU‐E‐T‐592: OSL Response of Al2O3:C Detectors Exposed to Therapeutic Proton Beams

2015· article· en· W1038155642 on OpenAlexaffabout
DA Granville, DB Flint, GO Sawakuchi

Bibliographic record

VenueMedical Physics · 2015
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsCarleton University
Fundersnot available
KeywordsOptically stimulated luminescenceDosimeterMaterials scienceAbsorbed doseOpticsDosimetryBeam (structure)ProtonIrradiationNanodotNuclear medicinePhysicsRadiationOptoelectronicsLuminescenceNuclear physicsMedicine

Abstract

fetched live from OpenAlex

Purpose: To characterize the response of Al2O3:C optically stimulated luminescence (OSL) detectors (OSLDs) exposed to therapeutic proton beams of differing beam quality. Methods: We prepared Al2O3:C OSLDs from the same material as commercially available nanoDot dosimeters (Landauer, Inc). We irradiated the OSLDs in modulated proton beams of varying quality, as defined by the residual range. An absorbed dose to water of 0.2 Gy was delivered to all OSLDs with the residual range values varying from 0.5 to 23.5 cm (average LET in water from ∼0.5 to 2.5 keV/µm). To investigate the beam quality dependence of different emission bands within the OSL spectrum, we performed OSLD readouts using both continuous‐wave stimulation (CW‐OSL) and pulsed stimulation (P‐OSL) with two sets of optical filters (Hoya U‐340 and Kopp 5113). For all readout modes, the relative absorbed dose sensitivity (Srel) for each beam quality was calculated using OSLDs irradiated in a 6 MV photon beam as a reference. Results: We found that the relative absorbed dose sensitivity was highly dependent on both readout mode and integration time of the OSL signal. For CW‐OSL signals containing only the blue emission band, Srel was between 0.85 and 0.94 for 1 s readouts and between 0.82 and 0.93 for 10 s readouts. Similarly, for P‐OSL readouts containing only the blue emission band Srel ranged from 0.86 to 0.91, and 0.82 to 0.93 for 1 s and 10 s readouts, respectively. For OSLD signals containing only the UV emission band, Srel ranged from 1.00 to 1.46, and 0.97 to 1.30 for P‐OSL readouts of 1 s and 10 s, respectively. Conclusion: For measurements of absorbed dose using Al2O3:C OSLDs in therapeutic proton beams, dependence on beam quality was smallest for readout protocols that selected the blue emission band with small integration times. DA Granville received financial support from the Natural Sciences and Engineering Research Council of Canada

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.284
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueMedical Physics→Same topicRadiation Detection and Scintillator Technologies→French-language works237,207→