MétaCan
Menu
Back to cohort
Record W111172760

Clinical characterization of spherical post-lens debris associated with lotrafilcon high-Dk silicone lenses.

2000· article· en· W111172760 on OpenAlexaff
Kathy Dumbleton, Lyndon Jones, Robin L. Chalmers, Donna Williams-Lyn, D. Fonn

Bibliographic record

VenuePubMed · 2000
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsMucinSilicone hydrogelKeratometerMedicineOphthalmologyContact lensLens (geology)Meridian (astronomy)CorneaPathologyOpticsPhysics
DOInot available

Abstract

fetched live from OpenAlex

PURPOSE: Experience with high Dk silicone hydrogel lenses has revealed post-lens debris, which is characterized by the appearance of spherical, translucent particles referred to as "mucin balls." The objectives of this analysis were to characterize the presence of mucin balls, determine whether any ocular characteristic predicts the development of mucin ball debris, and determine whether there is any association between mucin balls and the ocular response to contact lens wear. METHODS: Ninety-two subjects wore lotrafilcon A lenses on an extended wear basis for up to 30 nights and were followed for 6 months. Mucin balls were graded on a 0 to 4 scale at three visits. Subjective ratings and biomicroscopic appearance were recorded at all visits. RESULTS: Mucin balls were observed in 70% of subjects at one or more visits, and 29% of subjects at all three visits. There was no change in the mean grade of mucin balls over time. Mucin balls were graded > 1 in 20% of eyes, > 2 in 6% of eyes, and > 3 in 2% of eyes. Subjects who exhibited mucin balls at each clinical visit had significantly steeper keratometry readings along the flatter meridian (44.3 D) than those who never exhibited mucin balls (42.9 D, P < 0.0001). The percentage of subjects who "never" use lubricating drops was higher in the subjects with mucin balls (P = 0.0014). No association was found between mucin ball observation and biomicroscopic appearance, inflammatory responses, or subjective responses. CONCLUSIONS: The presence of mucin balls does not appear to be detrimental to contact lens wear. Eyes with steeper corneal curvature were significantly more likely to present with mucin ball debris, indicating they may be a function of lens fit. Clinical factors that may be modified in order to manage the more severe presentation of mucin balls are the use of lubricating drops and the number of nights extended wear schedule.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.418
Threshold uncertainty score0.551

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.233
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2000
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicOcular Surface and Contact LensFrench-language works237,207