MétaCan
Menu
Back to cohort
Record W118556985 · doi:10.1177/039139880703001210

Integration of Blood Volume, Blood Pressure, Heart Rate and Bioimpedance Monitoring for the Achievement of Optimal Dry Body Weight during Chronic Hemodialysis

2007· article· en· W118556985 on OpenAlexaff
M. Bonello, Andrew A. House, D. Cruz, Y. Asuman, Emilios Andrikos, Dimitris Petras, M. Strazzabosco, Federico Ronco, Alessandra Brendolan, C. Crepaldi, Federico Nalesso, Claudio Ronco

Bibliographic record

VenueThe International Journal of Artificial Organs · 2007
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsWestern University
Fundersnot available
KeywordsHemodialysisBlood pressureMedicineBlood volumePulse pressureIntravascular volume statusCardiologyHemodynamicsHeart rateInternal medicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Achieving optimal dry body weight in hemodialysis is challenging. Clinical assessment alone is inadequate, and methods such as bioimpedance monitoring may be impractical for every patient treatment. Continuous blood volume monitoring, blood pressure and heart rate variability inform clinical decision-making, but integrated use of multiple methodologies to achieve dry weight and understand patient factors has not yet been described. METHODS: Nineteen chronic hemodialysis patients underwent thrice-weekly treatments for two weeks. Baseline hydration status and target weight were determined by bioimpedance. During subsequent treatments, ultrafiltration was adjusted and relative blood volume, blood pressure and pulse were recorded non-invasively. Bioimpedance was repeated to assess hydration. Response of variables to progressive change in weight was assessed and selected patients underwent additional autonomic function testing. RESULTS: Four distinct hemodynamic patterns emerged. Profile A: 4 patients demonstrated overhydration at baseline. With decreasing target, pulse and blood pressure remained stable while blood volume and bioimpedance demonstrated achievement of dry weight. Profile B: 8 patients demonstrated overhydration at baseline. With decreasing target, blood pressure remained stable while pulse increased. Profile C: 5 patients were overhydrated, but as weight decreased, blood pressure became unstable and heart rate failed to compensate. Further testing confirmed autonomic dysfunction. Profile D: 2 patients were dehydrated, and with increasing target demonstrated stable pulse and pressure, while blood volume and bioimpedance revealed achievement of dry weight. CONCLUSIONS: Integrating existing non-invasive, continuous monitoring during hemodialysis enabled achievement of dry weight and identified distinct profiles of the patients, some with autonomic dysfunction. This strategy may contribute to achieving optimum dry weight while improving cardiovascular tolerability of hemodialysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.118
Threshold uncertainty score0.252

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.273
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueThe International Journal of Artificial OrgansSame topicDialysis and Renal Disease ManagementFrench-language works237,207