MétaCan
Menu
Back to cohort

VALIDATION OF TWO AND THREE-DIMENSIONAL RADIOGRAPHIC TECHNIQUES FOR MEASURING POLYETHYLENE WEAR AFTER TOTAL HIP ARTHROPLASTY

2003· article· en· W120745654 on OpenAlexaff
Andrew J. Hui, Richard W. McCalden, John M. Martell, Steven J. MacDonald, Robert B. Bourne, Cecil H. Rorabeck

Bibliographic record

VenueJournal of Bone and Joint Surgery · 2003
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsLondon Health Sciences Centre
Fundersnot available
KeywordsRadiographyTotal hip arthroplastyLinear correlationBiomedical engineeringPolyethyleneMedicineOrthodonticsNuclear medicineMaterials scienceMathematicsSurgeryComposite materialStatistics

Abstract

fetched live from OpenAlex

BACKGROUND: Three-dimensional radiographic techniques have been developed to estimate in vivo polyethylene wear of total hip replacements. We are not aware of any published study examining the accuracy of these in vivo methods. Our objective was to validate two radiographic techniques by comparing their results with those obtained directly from retrieved specimens. METHODS: A coordinate measuring machine was used to probe the interior bearing surface of seventeen acetabular liners that had been retrieved at revision surgery. Solid models were created to determine volumetric polyethylene loss and linear depth and direction of wear. Two in vivo radiographic techniques (PolyWare and the Martell Hip Analysis Suite) were used to calculate two-dimensional linear, three-dimensional linear, and volumetric wear. The radiographic analysis was done independently, and the results were compared with the known values of polyethylene wear derived with use of the coordinate measuring machine. RESULTS: Correlation coefficients comparing the values for two-dimensional and three-dimensional linear wear and volumetric wear derived with the PolyWare radiographic technique with the values derived with the coordinate measuring machine were r(2) = 0.78, r(2) = 0.75, and r(2) = 0.91, respectively (all p < 0.001), and the correlation coefficients comparing the values derived with the Martell Hip Analysis Suite radiographic technique with those derived with the coordinate measuring machine were r(2) = 0.80, r(2) = 0.84, and r(2) = 0.91, respectively (p < 0.001). The average absolute difference between the radiographic estimates and the results derived with the coordinate measuring machine was approximately 19% (range, 13% to 24%). CONCLUSIONS: There was good agreement between the wear estimates made with both in vivo techniques and the measurements of the retrieved polyethylene liners made with the coordinate measuring machine. Two-dimensional wear analysis (based on anteroposterior radiographs) accounted for most of the polyethylene wear, while one technique of three-dimensional wear analysis (PolyWare) demonstrated some additional wear in the lateral plane.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.041
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.070

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.041
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0030.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.241
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations161
Published2003
Admission routes1
Has abstractyes

Explore more