MétaCan
Menu
← all works

Polymer gel dosimetry

2010· review· en· 868 citations· W122927108 on OpenAlex· 10.1088/0031-9155/55/5/r01

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
none
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Not applicableConsensus signal: none
Genre
Candidate signal: ReviewConsensus signal: Review
Teacher disagreement score
0.987
Threshold uncertainty score
0.841
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.155
GPT teacher head0.461
Teacher spread
0.306 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Physics in Medicine and Biology
Topic
Advanced Radiotherapy Techniques
Field
Physics and Astronomy
Canadian institutions
Queen's UniversityUniversité de SherbrookeUniversity of Victoria
Funders
National Cancer Institute
Keywords
DosimeterDosimetryMaterials scienceImaging phantomBrachytherapyMedical physicsNuclear medicineAbsorbed doseRadiochemistryIrradiationBiomedical engineeringRadiation therapyMedicineChemistryPhysicsRadiologyNuclear physics
Has abstract in OpenAlex
yes