Polymer gel dosimetry
Why is this work in the frame?
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Full frame distilled prediction
Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
- Candidate categories
- none
- Consensus categories
- none
- Domain
- Candidate signal: noneConsensus signal: none
- Study design
- Candidate signal: Not applicableConsensus signal: none
- Genre
- Candidate signal: ReviewConsensus signal: Review
- Teacher disagreement score
- 0.987
- Threshold uncertainty score
- 0.841
- Validation status
machine_predicted_unvalidated·codex-gemma-dda1882f352a
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
- Teacher spread
- 0.306 · how far apart the two teachers sit on this one work
- Validation status
score_only:v0-immature-baseline· verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it
Abstract
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
The record
- Venue
- Physics in Medicine and Biology
- Topic
- Advanced Radiotherapy Techniques
- Field
- Physics and Astronomy
- Canadian institutions
- Queen's UniversityUniversité de SherbrookeUniversity of Victoria
- Funders
- National Cancer Institute
- Keywords
- DosimeterDosimetryMaterials scienceImaging phantomBrachytherapyMedical physicsNuclear medicineAbsorbed doseRadiochemistryIrradiationBiomedical engineeringRadiation therapyMedicineChemistryPhysicsRadiologyNuclear physics
- Has abstract in OpenAlex
- yes