MétaCan
Menu
Back to cohort
Record W138971096

Occlusion of the common and internal iliac arteries for aortoiliac aneurysm repair: experience with the Amplatzer vascular plug.

2009· article· en· W138971096 on OpenAlexaff
S Marlene Grenon, Joel E. Gagnon, York Hsiang, Ravi Sidhu, David C. Taylor, Jason Clement, Jerry Chen

Bibliographic record

VenuePubMed · 2009
Typearticle
Languageen
FieldMedicine
TopicAortic aneurysm repair treatments
Canadian institutionsSt. Paul's Hospital
Fundersnot available
KeywordsMedicineEndovascular aneurysm repairEmbolizationAneurysmInternal iliac arteryOcclusionRadiologyAbdominal aortic aneurysmSurgeryAortaRetrograde perfusionPerfusion
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: We sought to evaluate and describe our centre's experience with the Amplatzer vascular plug (AVP) for the occlusion of common and internal iliac arteries (CIA; IIA) during endovascular aortic aneurysm repair (EVAR). METHODS: We performed a retrospective analysis of 20 consecutive patients between October 2006 and December 2007, who underwent occlusion of the CIA or IIA before or during EVAR to prevent endoleak. RESULTS: Among these 20 patients, 21 occlusion procedures occurred and 20 were successful. In the only unsuccessful case, the patient had EVAR, but occlusion with an AVP was not possible because of severe narrowing at the origin of the vessel. Of the successfully treated patients, 2 presented with ruptured aneurysms, whereas the others had elective procedures. Eleven patients received aortouni-iliac grafts and femoral-femoral bypass, and 9 patients received a bifurcated stent graft. In 5 patients, the AVP occlusion and EVAR procedures were staged; in these cases occlusion occurred first, followed by EVAR on average 29 (standard deviation [SD] 23) days later. We deployed 7 AVPs in the CIA, whereas 13 were deployed in the IIA. The average diameter of the vessels occluded was 10 (SD 1) mm and the average size of the device used was 13 (SD 1) mm, representing a device diameter 28% (SD 2%) greater than the vessel diameter. We used a single device in 18 patients, whereas 2 devices were deployed in the same artery in 2 patients. Four patients underwent concomitant coil embolization. On follow-up computed tomography (CT) scans, all occlusion procedures were clinically successful. At the 14-month (SD 1 mo) follow-up, 4 patients had a small type-II endoleak unrelated to the occlusion procedure and 1 had a type-I endoleak that required graft limb extension. Four patients had buttock claudication but none had changes in sexual function, ischemic complications or device dislodgement on CT scans. CONCLUSION: The AVP is a safe and effective method to occlude the CIA and IIA in patients undergoing EVAR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.240
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2009
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicAortic aneurysm repair treatmentsFrench-language works237,207