MétaCan
Menu
Back to cohort
Record W1414154777 · doi:10.1089/end.2014.0011

Tracked Ultrasonography Snapshots Enhance Needle Guidance for Percutaneous Renal Access: A Pilot Study

2014· article· en· W1414154777 on OpenAlexafffund
Tamás Ungi, Darren Beiko, Michael Fuoco, Franklin King, Matthew Holden, Gábor Fichtinger, D. Robert Siemens

Bibliographic record

VenueJournal of Endourology · 2014
Typearticle
Languageen
FieldMedicine
TopicKidney Stones and Urolithiasis Treatments
Canadian institutionsQueen's University
FundersSoutheastern Ontario Academic Medical OrganizationCancer Care Ontario
KeywordsMedicineImaging phantomUltrasonographyNephrostomyPercutaneousPercutaneous nephrostomyRadiologySurgeryNuclear medicine

Abstract

fetched live from OpenAlex

BACKGROUND AND PURPOSE: Although ultrasonography-guided percutaneous nephrostomy is relatively safe, a number of factors make it challenging for inexperienced operators. A computerized needle navigation technique using tracked ultrasonography snapshots was investigated to determine whether performance of percutaneous nephrostomy by inexperienced users could be improved. METHODS: Ten operators performed the procedure on a phantom model with alternating needle guidance between conventional ultrasonography and tracked ultrasonography snapshots. The needle was reinserted until fluid backflow confirmed calyceal access. Needle trajectories were recorded using the real time needle navigation system for offline evaluation of operator performance. Recorded needle trajectories were used to measure needle motion path length inside the phantom tissue, number of reinsertions, total procedure time, and needle insertion time as end points of this study. RESULTS: Needle path length measured inside the phantom tissue was significantly lower with ultrasonography snapshots guidance (295.0±23.1 mm, average±standard error of the mean) compared with control procedures (977.9±144.4 mm, P<0.01). This was associated with a significantly lower number of needle insertion attempts with ultrasonography snapshots (average 1.27±0.10 vs 2.83±0.31, P<0.01). The total procedure time and the needle insertion time were also significantly lower with ultrasonography snapshots guidance. CONCLUSION: Tracked ultrasonography snapshots appear to improve the performance of percutaneous nephrostomy in these preliminary investigations, justifying further validation studies. The presented navigation system is reproducible because of commercially available hardware and open-source software components, facilitating its potential role in clinical practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.239
Threshold uncertainty score0.692

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.343
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueJournal of EndourologySame topicKidney Stones and Urolithiasis TreatmentsFrench-language works237,207