Bibliographic record
Abstract
In this retrospective study from a single centre,1 the authors have demonstrated that earlier implantation of a neurostimulator for various types of “voiding dysfunctions” yields a better result than that seen with delayed implantation.1 Interestingly, this was consistent in both types of dysfunctions, urgency-frequency and urinary retention. In another publication, Scheepens and colleagues,2 from the Netherlands, reviewed 211 of their patients who underwent percutaneous nerve evaluation to determine the clinical parameters that predict a positive response. They found that patients with urinary tract dysfunctions for a relatively long time have a significantly lower chance of a positive test compared with patients with dysfunction for a relatively short time. The cut-off point was less than 7 months versus 7 months or longer. The authors postulated that with sacral neuromodulation (SNM), the sensory and motor neural pathways of the lower urinary tract are probably being remodelled. They surmised that, if a disorder is present for a longer time, it may be more difficult to restore the normal balance between different reflexes. This is similar to the conclusions in the current study. Neural plasticity is the capacity for continuous alteration of the neural pathways and synapses of the living brain and nervous system in response to experience or injury.3 In nonneurogenic voiding dysfunctions, reflexes become operative that interfere with normal function. For example, with urgency or detrusor overactivity, abnormal sensory afferent activity may lead to an abnormal micturition reflex, possibly mediated by a loss of higher centre voluntary control. With nonneurogenic nonobstructive retention, the guarding reflexes that usually prevent incontinence and that are inhibited by the brain during voiding may be abnormally active. SNM may activate or “reset” somatic afferent inputs that will modulate the micturition reflex via several mechanisms and restore normal function. Pudendal afferent input from SNM may turn on voiding reflexes by suppressing the guarding reflex pathways and can turn off supraspinally mediated hyperactive voiding by blocking ascending sensory pathway inputs.4 The question is, does SNM work, and if so, for how long? The Ontario Ministry of Health and Long-Term Care conducted a technology assessment on SNM and reviewed international health technology assessments and English-language journal articles published from 2000 to November 2004, in addition to new unreported trials.5 They reported on 4 previous technology assessments: the National Institute for Clinical Excellence from Britain, the Australian Safety and Efficacy Register of New Interventional Procedures, the Medical Services Advisory Committee in Australia and the Blue Cross Blue Shield in the United States. These assessments consistently reported that SNM was an effective technology for managing urge incontinence, urgency-frequency and urinary retention in patients who did not respond to drug or behaviour therapy. Complication rates ranged from 33%–50%, but there were no incidences of permanent injury or death. The Ontario assessment reviewed 2 randomized clinical trials (RCTs) in patients with refractory urge incontinence; both showed significant improvements in voiding function. Three studies (1 RCT, 1 retrospective review and 2 prospective case series) showed significant improvement for urgency-frequency with or without chronic pelvic pain. One RCT and 1 case series also showed significant improvement for refractory urinary retention. Of 6 studies identified describing long-term follow-up, the follow-up periods ranged from 1.5 years to over 5 years. The success rate of ≥ 50% improvement in voiding function was 58%– 77%. Explantation rates were 12%–21%. Overall, there was a 33% surgical revision rate, and no serious injury or death was reported. The Ontario assessment concluded that there is level 2 evidence to support the effectiveness and safety of SNM for patients with refractory urge incontinence, urgency-frequency or urinary retention. This is a very high level of evidence, compared with many other surgical procedures. The document also outlined the number of Ontario residents who might benefit from SNM. Between 3842 and 12 565 individuals may qualify for SNM and 1263 to 6283 may have a successful stimulation test. Currently, there is only 1 site in Ontario where SNM is performed — the Toronto Western Hospital — and it is restricted to 12 patients per year. In the rest of Canada, there are 5 centres in 3 provinces. This article adds information about the natural history of untreated voiding dysfunction. Although there is still much to be learned about the mechanism of action of this technology, there is evidence of the benefit and a huge unmet need. Clearly, much more work must be done to expand this technology in Canada.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.012 | 0.058 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.007 | 0.006 |
| Bibliometrics | 0.015 | 0.018 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.003 | 0.002 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.002 | 0.001 |
| Insufficient payload (model declined to judge) | 0.008 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".