MétaCan
Menu
Back to cohort
Record W1482417522 · doi:10.1002/mrm.24152

Regional ventilation mapping of the rat lung using hyperpolarized <sup>129</sup>Xe magnetic resonance imaging

2012· article· en· W1482417522 on OpenAlexafffund
Marcus J. Couch, Alexei Ouriadov, Giles Santyr

Bibliographic record

VenueMagnetic Resonance in Medicine · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsRobarts Clinical TrialsWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchForskningsrådet om Hälsa, Arbetsliv och Välfärd
KeywordsVentilation (architecture)Magnetic resonance imagingNuclear magnetic resonanceLung ventilationNuclear medicineFlip angleChemistryLungMedicinePhysicsInternal medicineRadiology

Abstract

fetched live from OpenAlex

Lung ventilation was mapped in seven healthy male Sprague-Dawley rats (433 ± 24 g) using hyperpolarized ¹²⁹Xe magnetic resonance imaging (MRI) at 3.0 T, and validated with hyperpolarized ³He MRI under similar ventilator conditions. Ventilation maps were obtained using flip angle variation for offset of RF and relaxation (FAVOR) which is a multiple breath imaging technique that extracts the fractional ventilation parameter, r, on a pixel-by-pixel basis from the dynamic signal enhancement. r is defined as the fractional refreshment of gas per breath. Under the ventilator conditions used in this work, whole-lung measurements of fractional ventilation obtained using hyperpolarized ¹²⁹Xe were not significantly different from those obtained using hyperpolarized ³He (p = 0.8125 by a Wilcoxon matched pairs test). Fractional ventilation gradients calculated in the superior/inferior (S/I) and anterior/posterior (A/P) directions obtained using hyperpolarized ¹²⁹Xe were not significantly different from those obtained using hyperpolarized ³He (p = 0.9375 and p = 0.1563, for the S/I and A/P directions, respectively). Following baseline fractional ventilation measurements, one representative rat was challenged with methacholine and fractional ventilation measurements were performed over a time course of 10 min. A reduction and subsequent recovery in whole-lung r values were detected using the FAVOR method.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.290
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAtomic and Subatomic Physics ResearchFrench-language works237,207