MétaCan
Menu
Back to cohort

Immediate Occlusal Loading of Single Lower Molars Using Brånemark System® Wide Platform TiUnite™ Implants: A 5-Year Follow-Up Report of a Prospective Clinical Multicenter Study

2009· article· en· W1499141335 on OpenAlexvenueno aff
Roberto Calandriello, Massimiliano Tomatis

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2009
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersNational Institutes of Health
KeywordsMolarMedicineDentistryImplantOrthodonticsMandible (arthropod mouthpart)Surgery

Abstract

fetched live from OpenAlex

INTRODUCTION: Although not essential, molars hold their importance in terms of functional jaw stability, antagonist opposition, and support of facial height. Therefore, implant therapy is an attractive concept in molar areas. However, especially in the posterior mandible, the conventional two-stage surgical approach to implant therapy was reported to cause higher bone loss and/or higher implant failures with machined implants because of the peculiar anatomic and physiologic conditions of this area. As the TiUnite™ (Nobel Biocare AB, Göteborg, Sweden) surface results in faster bone healing than with machined-surface implants, it was hypothesized that this surface would also improve the performance of wide implants in posterior mandibles. Based on these assumptions, a protocol for immediately loaded implants for single molar replacement was developed. PURPOSE: This paper aimed to report on the clinical and radiological performance of Brånemark System® TiUnite Wide Platform implants supporting single molars in the lower jaw, loaded immediately and followed for up to 5 years, and to assess if the benefit delivered by oxidized surfaces in the short run is also present after 5 years. MATERIALS AND METHODS: The study includes 33 consecutive patients treated between March 2001 and September 2003 and monitored until September 2008 in two private dental offices. A total of 40 Brånemark System TiUnite Wide Platform MK III implants were placed. All implants were provided with provisional crowns in full centric occlusion at the time of surgery. Patients were clinically and radiologically followed up for up to 5 years. RESULTS: Two implant failed so that the cumulative success rate at 5 years was 95.0%. The mean marginal bone remodeling (n = 38) expressed as mesial plus distal value averages was -1.17 mm (SD ± 0.90) at the 5-year time point. CONCLUSION: Although limited by the number of patients treated in accordance with the protocol described, 5-year results encourage the use of immediately loaded single lower molars supported by Brånemark System Wide Platform TiUnite implants and further document the clinical advantages of titanium oxidized surfaces.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.136
GPT teacher head0.465
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207