2014· article· en· W1509665224 on OpenAlexaff
Meng Wu, Ramani Ramaseshan

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2014
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer Agency
Fundersnot available
KeywordsComputer scienceQuality assurancePlane (geometry)Orientation (vector space)Process (computing)Computer visionComputed tomographySimulationArtificial intelligenceOpticsPhysicsMathematicsGeometryMedicine

Abstract

fetched live from OpenAlex

The quality assurance tests for measuring the spatial orientations between tabletop, external patient positioning lasers, couch longitudinal moving direction, and imaging plane in a CT simulation system are a complicated and time-consuming process. We proposed a simple and efficient approach to acquire the angular deviations of spatial orientations between these components. An in-house cross-jig was used in this study. We found a relationship between the orientations of the jig's arms shown on the CT images and the orientations of the components in a CT simulator. We verified this relationship with 16 misalignment orientations of known errors, to simulate all possible deviation situations. Generally, the tabletop and external lasers system are mounted separately in a CT simulation system; the former is on the couch trail, the later is on the wall and ceiling. They are independent to each other and will cause different effects on CT images. We only need two scans to acquire the angular deviations of our system: i) when aligning the cross-jig with tabletop, we can check the orientations between the tabletop, couch longitudinal moving direction, and imaging plane; ii) while aligning the cross-jig with the external axial lasers, we will know the angular deviation between the lasers, couch longitudinal moving direction, and imaging plane. The CT simulator had been carefully examined by performing the QA procedures recommended by the AAPM Task Group 66. The measurements of the spatial orientations using the proposed method agree well with TG 66 recommendations. However, the time taken to perform the QA using our method is considerably shorter than the method described in TG 66--5 minutes versus 30 minutes. The deliberate misalignment orientations tests with known errors were detected successfully by our in-house analysis program. The maximum difference between the known errors and the measured angles is only 0.07°. We determined that the relationship between the orientations of the jig's arms and the orientations of the CT components. By means of quantifying the deviations in degree we can correct the errors accurately. This approach can also be used to inspect the spatial orientations of other imaging systems, such as PET-CT and MRI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.358
Teacher spread0.327 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207