MétaCan
Menu
Back to cohort
Record W1521616282 · doi:10.1120/jacmp.v13i3.3767

Total body irradiation dose optimization based on radiological depth

2012· article· en· W1521616282 on OpenAlexafffund
Amjad Hussain, Peter Dunscombe, J. Eduardo Villarreal‐Barajas, Derek W. Brown

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Calgary
FundersCentre Hospitalier Universitaire de Québec
KeywordsImaging phantomAperture (computer memory)FluenceMultileaf collimatorNuclear medicineOpticsBeam (structure)DosimetryMaterials sciencePhysicsMedicineLinear particle acceleratorAcousticsLaser

Abstract

fetched live from OpenAlex

We have previously demonstrated the use of Eclipse fluence optimization to define aperture sizes for a novel aperture modulated translating bed total body irradiation (TBI) technique. The purposes of the present study were to identify, characterize, and correct for sources of error inherent in our previous fluence optimization technique, and to develop a clinically viable fluence optimization module for the translating bed TBI technique. Aperture modulated TBI is delivered by translating the patient at constant speed on a custom bed under a modulated radiation beam. The patient is then turned from supine to prone and the process repeated, resulting in an AP-PA treatment. Radiological depths were calculated along divergent ray lines through individual CT slices of a RANDO phantom. Beam apertures, defined using a dynamic multileaf collimator (DMLC), were generated using calculated radiological depths and calibration factors that relate fluence to aperture size in a dynamic environment. These apertures were defined every 9 mm along the phantom superior-inferior axis. The calculated beam apertures were further modified to account for scatter within the patient. For dose calculation purposes the individual MLC files were imported into Eclipse. For treatment delivery, dynamic MLC files for both AP and PA beams were generated and delivered dynamically. Dose homogeneity in the head and neck region of the RANDO phantom was within ± 4% of the prescribed dose with this novel technique compared to -5% to +7% with our previous aperture modulated technique based on Eclipse fluence optimization. Fluence optimization and beam aperture calculation using the new technique offers a ten-fold reduction in planning time and significantly reduces the likelihood of user error during the planning process. In conclusion, a clinically viable aperture modulated translating bed TBI technique that employs dynamically shaped MLC-defined beam apertures based on radiological depth calculations, has been developed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.354
Teacher spread0.329 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207