MétaCan
Menu
Back to cohort
Record W1522764101 · doi:10.1002/elps.201200286

Integrated electrokinetic sample fractionation and solid‐phase extraction in microfluidic devices

2012· article· en· W1522764101 on OpenAlexaff
Zhen Wang, Abebaw B. Jemere, D. Jed Harrison

Bibliographic record

VenueElectrophoresis · 2012
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsNational Research Council CanadaNational Institute for NanotechnologyUniversity of Alberta
Fundersnot available
KeywordsElectrokinetic phenomenaMicrofluidicsMonolithChromatographyFractionationSolid phase extractionPolymerField flow fractionationSample preparationElutionFoam fractionationMonolithic HPLC columnMaterials scienceExtraction (chemistry)ChemistryAnalytical Chemistry (journal)NanotechnologyHigh-performance liquid chromatography

Abstract

fetched live from OpenAlex

A microfluidic device that performs "in space" sample fractionation, collection, and preconcentration for proteomics is described. Effluents from a 2.75 mm long fractionation channel, focused via sheath flow, were sequentially delivered into an array of 36-collection channels containing monolithic polymer beds for SPE. Optimum conditions for the device design, and simultaneous photolytic fabrication of 36 monolithic columns in the 36 channels, as well as for their proper performance in electrokinetic sample fractionation and collection are described. A hydrophobic butyl methacrylate-based monolithic porous polymer was copolymerized with an ionizable monomer, acryloamido-methyl-propane sulfonate, to form a polymer monolith for SPE that also sustains cathodic electroosmotic flow. The SPE bed was made deep enough to greatly reduce the linear flow rate within the bed, in order to compensate for the lower electroosmotic mobility of the cationically charged SPE bed relative to the glass walled device. Under these conditions, electrokinetic fractionation of a protein sample resulted in tightly focused sample zones delivered into each of the 36-channel polymer beds with no observed crosscontamination. Monolithic columns showed reproducible performance with preconcentration factor of 30 for 2 min loading time. The ability to fractionate, collect, and preconcentrate samples on a microfluidic platform will be especially useful for automated or continuous operation of these devices in proteomics research.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.261
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueElectrophoresisSame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207