Bibliographic record
Abstract
Flat-panel cone beam CT is maturing to a stable imaging modality. Applications are being developed for radiotherapy, volumetric diagnostic scanning, rotational angiography and mobile C-arm technologies with soft tissue imaging capabilities. Volumetric image-guided radiotherapy is technologically feasible, and has been proven clinically useful with cone beam CT, CT on rails and tomotherapy design configurations. Soft-tissue-based guidance of field placement is now possible for many sites. Evaluation of the relative merits of these technologies requires that the objective of imaging be well defined. Relevant questions include: Can the target or normal structure of interest be localized with the desired precision and accuracy? Can the patient's position be adjusted based on this information within the time constraints of the clinical workload? We must be prepared to compromise diverse clinical objectives and technical features in order to achieve systems with defined and useful functionality. These imaging technologies will lead to a better understanding of the weaknesses, and provide opportunity to reduce errors and improve technical execution of radiotherapy delivery.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".