MétaCan
Menu
Back to cohort

Swallowing accelerometry signal feature variations with sensor displacement

2015· article· en· W1529581252 on OpenAlexafffund
Khondaker A. Mamun, Catriona M. Steele, Tom Chau

Bibliographic record

VenueMedical Engineering & Physics · 2015
Typearticle
Languageen
FieldHealth Professions
TopicDysphagia Assessment and Management
Canadian institutionsHolland Bloorview Kids Rehabilitation HospitalToronto Rehabilitation InstituteUniversity of TorontoUniversity Health Network
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsAccelerometerSIGNAL (programming language)Artificial intelligenceSignal processingQUIETFeature (linguistics)Computer sciencePattern recognition (psychology)Computer visionPhysicsDigital signal processing

Abstract

fetched live from OpenAlex

First study to systematically evaluate the effect of positional offsets of sensor location on dualaxes swallowing accelerometry signals. Sensor can be displaced 4 mm inferior to and 6 mm superior to the baseline position (midline on neck, below thyroid cartilage) without significantly altering time-frequency signal features. Sensor can be displaced 4 mm lateral to the baseline position without significantly altering timefrequency signal features. Time-frequency features are more robust to positional offsets of sensor than time domain and frequency domain features. Classification of swallowing conditions based on swallow accelerometry should consider time-frequency features if positional robustness of sensor placement is important. Dual-axis accelerometry has recently shown promise as a non-invasive method for detecting swallowing impairment using signal processing and pattern classification algorithms. However, it is unknown whether variations in sensor placement alter signal characteristics, threatening the accuracy of signal processing classifiers for aspiration detection. To address this question, water swallows were recorded in 14 healthy adults using a dual-axis accelerometer in 13 different positions (baseline, and 2, 4, 6 and 8 mm above, below and to the right of baseline). The baseline position was midline, immediately below the thyroid cartilage during quiet breathing. After segmentation and pre-processing, signal features were extracted in multiple domains (time, frequency, time-frequency). The effect of sensor position on signal feature distributions was examined with non-parametric statistical analysis. The analysis showed that the sensor could be displaced by as much as 4 mm inferior and lateral to the baseline position and by up to 6 mm above the baseline location without significantly altering time-frequency features. In other words, when considering the baseline position as the origin, the admissible region for sensor placement spans 10 mm in the superior-inferior axis and 8 mm in the medial-lateral direction. Results of this study suggest that time-frequency representations of accelerometry signals are most robust to sensor placement variations around the baseline position. The implication of this finding is that a swallowing accelerometry classifier based on time-frequency features can likely tolerate small variations in sensor location without degradation in classification performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.956
Threshold uncertainty score0.590

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.346
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueMedical Engineering & PhysicsSame topicDysphagia Assessment and ManagementFrench-language works237,207