Early Failure of the Biotronik Linox Implantable Cardioverter Defibrillator Lead
Bibliographic record
Abstract
INTRODUCTION: The Linox and Durata implantable cardioverter defibrillator (ICD) leads were introduced to British Columbia (BC) in 2008. We determined their performance and the potential risk factors for lead failure in a large population-based patient registry. METHODS AND RESULTS: We used the BC Cardiac Registry, a mandatory Governmental database of ICD implants, to identify all recipients of Linox and Durata leads in BC between October 2008 and April 2012, and those subsequently undergoing reoperation. Lead failure was defined as recurrent nonphysiological high-rate sensing unrelated to external electromagnetic interference or T-wave oversensing; a sudden rise in impedance unrelated to perforation or lead dislodgement; or abnormal lead parameters with definite evidence of lead fracture or insulation failure. We determined the estimated cumulative lead survival by the Kaplan-Meier method, and the risk factors for lead failure in a proportional hazards model. Over a median of 39 (27-50) months, the Linox failed more frequently than the Durata (16/477 [3.4%] vs. 4/838 [0.4%]; P < 0.001), and had a significantly lower estimated cumulative survival (91.6 [80.6-96.5]% vs. 99.4 [98.4-99.8]% at 5 years; P < 0.0001). Linox failure was characterized by high-rate nonphysiological sensing (11 cases), and/or a sudden impedance rise (7 cases). Insulation failure was clearly confirmed in 6 cases of Linox failure. Female sex was a significant risk factor for Linox failure (adjusted HR = 2.1[1.3-3.4]; P = 0.004). CONCLUSIONS: This multicenter registry indicates a high rate of Linox lead failure, particularly in female patients. Ongoing surveillance of the Linox ICD lead performance is recommended.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.003 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".