First‐in‐human valve‐in‐valve implantation of a 20 mm balloon expandable transcatheter heart valve
Bibliographic record
Abstract
An 86-year-old lady with recurrent admissions for heart failure due to a severely regurgitant aortic bioprosthesis (SJM Epic 19 mm) was not a candidate for re-operation due to age and frailty. Her small ilio-femoral arteries precluded a transfemoral transcatheter valve-in-valve (VIV) approach. The small internal diameter of her bioprosthesis (16 mm) forbids the implantation of the smallest available transapical transcatheter heart valve (THV). We, therefore, decided to perform a first-in-human transapical aortic VIV implantation using a 20 mm balloon expandable THV and a transfemoral delivery system. The procedure was successfully performed under general anesthesia, without any contrast dye and under fluoroscopy as well as transesophageal echocardiography guidance. The post-procedural transvalvular gradient was 15 mm Hg (pre-procedural 14 mm Hg). At 30-day follow-up, the lady was living independently at home without shortness of breath during her daily activities. If redo-surgery for prosthetic regurgitation is not an option, VIV implantation in very small surgical bioprosthesis is feasible and leads to acceptable hemodynamics and clinical improvement.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.010 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".