Cryolipolysis for safe and effective inner thigh fat reduction
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND AND OBJECTIVES: While cryolipolysis initially received FDA clearance for fat reduction in the abdomen and flanks, there was significant interest in non-surgical fat reduction for other sites, such as the inner and outer thighs. This article reports the results of an inner thigh study which contributed to FDA clearance of cryolipolysis for treatment of thighs. STUDY DESIGN/MATERIAL AND METHODS: A flat cup vacuum applicator (CoolFit applicator, CoolSculpting System) was used to treat 45 subjects bilaterally in the inner thighs. Single cycle treatments were delivered at Cooling Intensity Factor (CIF) 41.6 for 60 minutes followed by 2 minutes of manual massage. Follow-up visits were conducted at 8 and 16 weeks. Efficacy was assessed by ultrasound imaging, circumference measurements, and photographs. Safety was assessed by monitoring adverse events. Patient satisfaction was evaluated by questionnaire. RESULTS: Data is presented for n = 42 patients that completed the 16 week study follow-up and maintained their weight within 5 lbs. of baseline. Independent photo review from three blinded physicians found 91% correct identification of baseline clinical photographs. Ultrasound data indicate fat layer reduction of 2.8 mm. Circumferential measurements indicate mean reduction of 0.9 cm. Patient questionnaires reveal 93% were satisfied with the CoolSculpting procedure; 84% noticed visible fat reduction; 89% would recommend to a friend; and 91% were likely to have a second treatment. There were no device- or procedure-related serious adverse events. CONCLUSION: The CoolFit flat cup vacuum applicator was found to deliver safe and effective cryolipolysis treatment to reduce inner thigh fat. Completed 16-week data from 42 subjects show 2.8 mm reduction in fat thickness and 0.9 cm reduction in circumference. Assessment of clinical photographs found 91% correct identification of baseline images. The results of this prospective, multi-center, interventional clinical study contributed to FDA clearance of cryolipolysis for treatment of thighs in April 2014.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it