Reliability of Circumferential Bone Level Assessment around Single Implants in Healed Ridges and Extraction Sockets Using Cone Beam CT
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
PURPOSE: Cone beam computerized tomography (CBCT) provides three-dimensional information and could absolutely be useful for evaluating circumferential implant bone levels. However, the accuracy and precision of the technique has not been described. The aim of the study was to assess the accuracy and precision of CBCT (i-CAT®, Imaging Sciences International®, Hatfield, PA, USA) using periapical radiographs (PA) as a reference and to evaluate the circumferential bone level on CBCT around immediately loaded single implants placed in healed ridges (CIT, conventional implant treatment) and extraction sockets (IIT, immediate implant placement). MATERIALS AND METHODS: PA and CBCT radiographs were obtained from 26 single Astra Tech Osseospeed™ implants (Astra Tech AB, Mölndal, Sweden) 1 year after loading in respectively healed ridges (CIT) or extraction socket (IIT). For accuracy analysis, the three mesial and three distal interproximal levels obtained by CBCT were pooled to enable a comparison with PA. Precision was analyzed by intra- and interexaminer reliability calculation from mesial and distal sites on CBCT. The circumferential bone level considered all eight positions assessed on CBCT. RESULTS: Accuracy of CBCT was low (R = 0.325/p = .019) given the fact that bone level of the total group was 0.70 mm (standard deviation [SD] 0.78, range 0.00-3.20) on PA and 0.23 mm (SD 0.27, 0.00-1.20) on CBCT (p < .001) with only 42% of the measurements showing deviation within 0.2 mm. However, intra- and interexaminer reliability were favorable (R ≥ 0.611/p < .001, ≥ 83%). The mean circumferential bone level on CBCT was 0.21 mm (SD 0.30) and 0.26 mm (SD 0.18) for IIT and CIT, respectively. The impact of the treatment strategy was not significant. CONCLUSION: PA should be the standard technique to assess interproximal bone level but correlates poorly with the CBCT measurements. However, the precision of CBCT was high. CBCT requires further improvements of hardware and/or software. Within the limitations of the study, there is an indication that the buccal bone 1 year after implant treatment is evenly preserved when implants are immediately loaded in extraction sockets or in healed bone.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.004 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.002 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it