MétaCan
Menu
Back to cohort
Record W1552689321 · doi:10.3171/2012.7.gks121016

Reliability of contour-based volume calculation for radiosurgery

2012· article· en· W1552689321 on OpenAlexaff
Lijun Ma, Arjun Sahgal, Ke Nie, Andrew Hwang, Aliaksandr Karotki, Brian Wang, Dennis C. Shrieve, Penny K. Sneed, Michael McDermott, David A. Larson

Bibliographic record

VenueJournal of neurosurgery · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer CentreSunnybrook Health Science Centre
Fundersnot available
KeywordsRadiosurgeryImaging phantomVolume (thermodynamics)Quality assuranceMedicineReliability (semiconductor)Nuclear medicineComputer scienceRadiologyRadiation therapy

Abstract

fetched live from OpenAlex

OBJECT: Determining accurate target volume is critical for both prescribing and evaluating stereotactic radiosurgery (SRS) treatments. The aim of this study was to determine the reliability of contour-based volume calculations made by current major SRS platforms. METHODS: Spheres ranging in diameter from 6.4 to 38.2 mm were scanned and then delineated on imaging studies. Contour data sets were subsequently exported to 6 SRS treatment-planning platforms for volume calculations and comparisons. This procedure was repeated for the case of a patient with 12 metastatic lesions distributed throughout the brain. Both the phantom and patient datasets were exported to a stand-alone workstation for an independent volume-calculation analysis using a series of 10 algorithms that included approaches such as slice stacking, surface meshing, point-cloud filling, and so forth. RESULTS: Contour data-rendered volumes exhibited large variations across the current SRS platforms investigated for both the phantom (-3.6% to 22%) and patient case (1.0%-10.2%). The majority of the clinical SRS systems and algorithms overestimated the volumes of the spheres, compared with their known physical volumes. An independent algorithm analysis found a similar trend in variability, and large variations were typically associated with small objects whose volumes were < 0.4 cm(3) and with those objects located near the end-slice of the scan limits. CONCLUSIONS: Significant variations in volume calculation were observed based on data obtained from the SRS systems that were investigated. This observation highlights the need for strict quality assurance and benchmarking efforts when commissioning SRS systems for clinical use and, moreover, when conducting multiinstitutional cross-SRS platform clinical studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.070
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.012
Threshold uncertainty score0.065

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.070
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.285
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueJournal of neurosurgerySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207