MétaCan
Menu
Back to cohort
Record W1555290664 · doi:10.1111/jce.12496

Positive Response to Cardiac Resynchronization Therapy Reduces Arrhythmic Events After Elective Generator Change in Patients with Primary Prevention CRT‐D

2014· article· en· W1555290664 on OpenAlexaff
F. Sébag, Nicolas Lellouche, Zhong Chen, A. Tritar, Mark O’Neill, Jaswinder Gill, Matthew Wright, Christophe Leclercq, Christopher A. Rinaldi

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSt. Thomas Hospital
Fundersnot available
KeywordsMedicineCardiac resynchronization therapyEjection fractionInternal medicineCardiologyHeart failureImplantable cardioverter-defibrillatorHazard ratioArtificial cardiac pacemakerVentricular dyssynchronyConfidence interval

Abstract

fetched live from OpenAlex

INTRODUCTION: Cardiac resynchronization therapy (CRT) and implantable cardioverter-defibrillators (ICD) are effective therapies for heart failure (HF) patients with cardiac dyssynchrony. Patients receiving primary prevention CRT-defibrillator that positively remodel might no longer qualify for ICD indication due to CRT-induced left ventricular ejection fraction (LVEF) improvement. We aimed to evaluate the outcome of CRT-D patients at the time of device replacement (DR). METHODS AND RESULTS: Patients undergoing primary prevention CRT-D DR were prospectively included from November 2007 to March 2011 in 2 centers. CRT response was as defined as ≥1 NYHA class improvement and an increase in LVEF ≥10%. Before DR, all patients underwent echocardiography and device interrogation. Patients without theoretical ongoing ICD indication (TOII) at DR were defined as those with LVEF ≥40% without appropriate ICD therapy (appropriate therapy) during the first ICD service-life. A total of 107 consecutive patients were enrolled. Sixty-one patients (57%) were considered CRT responders after the index procedure. At the time of DR (56.4 ± 14.4 months from initial implant), 87% of CRT responders were free of appropriate therapy, compared with 70% of CRT nonresponders (P = 0.02). Thirty-nine patients (37%) did not meet the criteria for TOII. During follow-up (mean 26.4 ± 14.4 months after DR), 37 patients (95%) without TOII were free of appropriate therapy versus 49 of 68 patients (72%) with ongoing TOII (P = 0.007). By multivariable analysis, the only independent predictor of appropriate therapy after DR was TOII (hazard ratio = 6.43; P = 0.01). CONCLUSION: Absence of theoretical ICD indication occurs in more than one-third of CRT-D patients undergoing DR. In addition, appropriate therapy rate is relatively low (2.2% per year) in this subgroup of patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.803
Threshold uncertainty score0.642

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.237
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207