Preliminary results of an automatic channel fault detection system on a small animal APD-based digital PET scanner

2013· article· en· W1555813757 on OpenAlexaffabout
Jonathan Charest, Jean-François Beaudoin, J. Cadorette, Roger Lecomte, Charles-Antoine Brunet, Réjean Fontaine

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversité de Sherbrooke
Fundersnot available
KeywordsComputer scienceChannel (broadcasting)ScannerArtificial intelligenceHistogramFault detection and isolationComputer visionElectronic engineeringReal-time computingEngineeringTelecommunications

Abstract

fetched live from OpenAlex

APD-based positron emission tomography scanners show enhanced imaging capabilities in terms of spatial resolution and contrast due to the one to one coupling and size of individual crystal-APD detectors. However, to ensure maximum performance, these PET scanners require proper calibration by qualified professionals, which can become a cumbersome task because of the large number of channels present. An intelligent system (IS) intends to alleviate this workload by enabling a diagnosis of the observational errors of the scanner. The IS can be broken down into four hierarchical blocks: parameter extraction, channel fault detection, prioritization and diagnosis. One of the main function of the IS consists of analyzing available channel data such as: normalization coincidence counts and single count rates, crystal identification classification data, energy histograms, APD bias and noise thresholds to establish the channel's health status that will be used to detect channel faults. This paper focuses on the first two blocks of the IS: parameter extraction and channel fault detection. The purpose of the parameter extraction block is to process available channel data into parameters that are subsequently used by the fault detection block to generate the channel's health status. To ensure extensibility, the channel fault detection block is divided into indicators representing different aspects of the PET scanner performance: sensitivity, timing, identification and energy. Some experiments on a LabPET scanner located at the Sherbrooke Molecular Imaging Center demonstrated an erroneous channel fault detection rate of 6% (with a 95% confidence interval (CI) of: [5, 6]) which is considered tolerable. Globally, the IS achieves a channel fault detection efficiency of 95% (CI: [92, 97]), which proves many faults can be detected automatically. Increased fault detection efficiency would be advantageous but, the achieved results would already benefit professionals in their maintenance task.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.266
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes2
Has abstractyes

Explore more

Same topicMedical Imaging Techniques and Applications→French-language works237,207→