MétaCan
Menu
Back to cohort
Record W1558791662 · doi:10.1111/bju.13016

A trial of devices for urinary incontinence after treatment for prostate cancer

2014· article· en· W1558791662 on OpenAlexaff
Margaret Macaulay, Jackie Broadbridge, Heather Gage, Peter Williams, Brian Birch, Alan Cottenden, Mandy Fader

Bibliographic record

VenueBritish Journal of Urology · 2014
Typearticle
Languageen
FieldMedicine
TopicPelvic floor disorders treatments
Canadian institutionsUniversity of Alberta
FundersEngineering and Physical Sciences Research CouncilProstate Cancer UKAstellas PharmaUniversity of SouthamptonPfizer
KeywordsMedicineUrinary incontinenceProstate cancerQuality of life (healthcare)Physical therapyRandomized controlled trialSurgeryClampCancerInternal medicineNursing

Abstract

fetched live from OpenAlex

OBJECTIVE: To compare the performance of three continence management devices and absorbent pads used by men with persistent urinary incontinence (>1 year) after treatment for prostate cancer. PATIENTS AND METHODS: Randomised, controlled trial of 56 men with 1-year follow-up. Three devices were tested for 3 weeks each: sheath drainage system, body-worn urinal (BWU) and penile clamp. Device and pad performance were assessed. Quality of life (QoL) was measured at baseline and follow-up with the King's Health Questionnaire. Stated (intended use) and revealed (actual use) preference for products were assessed. Value-for-money was gathered. RESULTS: Substantial and significant differences in performance were found. The sheath was rated as 'good' for extended use (e.g. golf and travel) when pad changing is difficult; for keeping skin dry, not leaking, not smelling and convenient for storage and travel. The BWU was generally rated worse than the sheath and was mainly used for similar activities but by men who could not use a sheath (e.g. retracted penis) and was not good for seated activities. The clamp was good for short vigorous activities like swimming/exercise; it was the most secure, least likely to leak, most discreet but almost all men described it as uncomfortable or painful. The pads were good for everyday activities and best for night-time use; most easy to use, comfortable when dry but most likely to leak and most uncomfortable when wet. There was a preference for having a mixture of products to meet daytime needs; around two-thirds of men were using a combination of pads and devices after testing compared with baseline. CONCLUSIONS: This is the first trial to systematically compare different continence management devices for men. Pads and devices have different strengths, which make them particularly suited to certain circumstances and activities. Most men prefer to use pads at night but would choose a mixture of pads and devices during the day. Device limitations were important but may be overcome by better design.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.029

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.003
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0090.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.294
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of UrologySame topicPelvic floor disorders treatmentsFrench-language works237,207