MRI measurement of dynamics of the liquid and a dissolved gas during acoustic cavitation
Bibliographic record
Abstract
A study was conducted to perform magnetic resonance imaging (MRI) measurement of dynamics of the liquid and dissolved gas during acoustic cavitation. The study focused on obtaining information on dynamics of molecules that constituted the bubbles and the surrounding liquid. The information was acquired directly using the MRI techniques of measuring the displacement and the relaxation parameters of water along with an NMR-sensitive highly soluble gas as a function of the acoustic pressure and the water preparation procedures. The obtained data were examined using a two-site exchange model to extract estimates of the average residence time of gas molecules inside the cavitating bubbles. The cavitation onset was detected at 0.6 Atm in the tap water and at 0.7 Atm in the filtered water by the appearance of the high frequency noise detected by the hydrophone.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".